Auto-update blog content from Obsidian: 2025-08-26 18:41:22
All checks were successful
Blog Deployment / Check-Rebuild (push) Successful in 6s
Blog Deployment / Build (push) Has been skipped
Blog Deployment / Deploy-Staging (push) Successful in 11s
Blog Deployment / Test-Staging (push) Successful in 2s
Blog Deployment / Merge (push) Successful in 6s
Blog Deployment / Deploy-Production (push) Successful in 10s
Blog Deployment / Test-Production (push) Successful in 2s
Blog Deployment / Clean (push) Has been skipped
Blog Deployment / Notify (push) Successful in 3s

This commit is contained in:
Gitea Actions
2025-08-26 18:41:22 +00:00
parent 2c5f8e14dd
commit a71cba5e61
4 changed files with 4 additions and 4 deletions

View File

@@ -142,7 +142,7 @@ Pour pouvoir ajuster la température sans avoir à modifier tout le workflow, j
Ces valeurs représentent la température de base utilisée pour le calcul des seuils, en fonction des offsets que je détaillerai plus loin.
Le premier nœud est un `trigger state node` qui regroupe les 6 entités. Si je modifie lune de ces valeurs, le nœud est déclenché :
![Node-RED trigger state node for sliders](img/node-red-trigger-state-nmode-for-sliders.png)
![Node-RED trigger state node for sliders](img/node-red-trigger-state-mode-for-sliders.png)
Le deuxième nœud est un `function node`, qui permet de déterminer la pièce concernée :
```js
@@ -675,7 +675,7 @@ Parfois, pour une raison ou une autre, on souhaite utiliser la climatisation man
Node-RED utilise son propre utilisateur dans Home Assistant, donc si une unité change détat sans cet utilisateur, cest quune intervention manuelle a eu lieu.
Le premier nœud est un `trigger state node`, qui envoie un message dès quune unité AC change détat :
![Pasted_image_20250626221149.png](img/Pasted_image_20250626221149.png)
![node-red-trigger-state-unit-change.png](img/node-red-trigger-state-unit-change.png)
Le deuxième est un `function node` qui associe lunité avec son minuteur :