Auto-update blog content from Obsidian: 2025-09-28 17:28:00
All checks were successful
Blog Deployment / Check-Rebuild (push) Successful in 6s
Blog Deployment / Build (push) Has been skipped
Blog Deployment / Deploy-Staging (push) Successful in 10s
Blog Deployment / Test-Staging (push) Successful in 3s
Blog Deployment / Merge (push) Successful in 7s
Blog Deployment / Deploy-Production (push) Successful in 9s
Blog Deployment / Test-Production (push) Successful in 2s
Blog Deployment / Clean (push) Has been skipped
Blog Deployment / Notify (push) Successful in 3s

This commit is contained in:
Gitea Actions
2025-09-28 17:28:00 +00:00
parent 452f4497b2
commit 62f267dad4
2 changed files with 54 additions and 2 deletions

View File

@@ -213,9 +213,61 @@ Now I can safely sync my services like described above, this will only propagate
The last thing I need to configure is the WAN interface, my ISP box is only giving me one IP address over DHCP, I don't want my 2 VMs compete to claim it. To handle that, I will give my 2 VMs the same MAC for the WAN interface, then I need to find a solution to enable the WAN interface only on the master node.
In Proxmox WebGUI, I copy the MAC address of the net0 interface (*POC WAN*) from `poc-opnsense-1` and paste it to the one in `poc-opnsense-2`.
In the Proxmox WebGUI, I copy the MAC address of the net0 interface (*POC WAN*) from `poc-opnsense-1` and paste it to the one in `poc-opnsense-2`.
To handle the activation of the WAN interface on the master node while deactivating the backup, I could use a script. On CARP event, scripts located in `/usr/local/etc/rc.syshood.d/carp` are played. I found this [Gist](https://gist.github.com/spali/2da4f23e488219504b2ada12ac59a7dc#file-10-wancarp) which is exactly what I wanted.
I copy this script in `/usr/local/etc/rc.syshood.d/carp/10-wan` on both nodes:
```php
#!/usr/local/bin/php
<?php
require_once("config.inc");
require_once("interfaces.inc");
require_once("util.inc");
require_once("system.inc");
$subsystem = !empty($argv[1]) ? $argv[1] : '';
$type = !empty($argv[2]) ? $argv[2] : '';
if ($type != 'MASTER' && $type != 'BACKUP') {
log_error("Carp '$type' event unknown from source '{$subsystem}'");
exit(1);
}
if (!strstr($subsystem, '@')) {
log_error("Carp '$type' event triggered from wrong source '{$subsystem}'");
exit(1);
}
$ifkey = 'wan';
if ($type === "MASTER") {
log_error("enable interface '$ifkey' due CARP event '$type'");
$config['interfaces'][$ifkey]['enable'] = '1';
write_config("enable interface '$ifkey' due CARP event '$type'", false);
interface_configure(false, $ifkey, false, false);
} else {
log_error("disable interface '$ifkey' due CARP event '$type'");
unset($config['interfaces'][$ifkey]['enable']);
write_config("disable interface '$ifkey' due CARP event '$type'", false);
interface_configure(false, $ifkey, false, false);
}
```
### Test Failover
Time for testing! OPNsense provides a way to enter CARP maintenance mode. Before pushing the button, my master has its WAN interface enabled and the backup doesn't:
![opnsense-vm-carp-status.png](img/opnsense-vm-carp-status.png)
Once I enter the CARP maintenance mode, the master node become backup and vice versa, the WAN interface get disabled while it's enabling on the other node. I was pinging outside of the network while switching and experienced not a single drop!
Finally, I simulate a crash by powering off the master and the magic happens! Here I have only one packet lost and, thanks to the firewall state sync, I can even keep my SSH connection alive.
## Conclusion
To handle the activation WAN interface on the master node

Binary file not shown.

After