Auto-update blog content from Obsidian: 2026-04-29 19:59:52
Some checks failed
Blog Deployment / Check-Rebuild (push) Successful in 8s
Blog Deployment / Build (push) Successful in 31s
Blog Deployment / Deploy-Staging (push) Successful in 9s
Blog Deployment / Test-Staging (push) Failing after 3s
Blog Deployment / Merge (push) Has been skipped
Blog Deployment / Deploy-Production (push) Has been skipped
Blog Deployment / Test-Production (push) Has been skipped
Blog Deployment / Clean (push) Has been skipped
Blog Deployment / Notify (push) Successful in 3s
Some checks failed
Blog Deployment / Check-Rebuild (push) Successful in 8s
Blog Deployment / Build (push) Successful in 31s
Blog Deployment / Deploy-Staging (push) Successful in 9s
Blog Deployment / Test-Staging (push) Failing after 3s
Blog Deployment / Merge (push) Has been skipped
Blog Deployment / Deploy-Production (push) Has been skipped
Blog Deployment / Test-Production (push) Has been skipped
Blog Deployment / Clean (push) Has been skipped
Blog Deployment / Notify (push) Successful in 3s
This commit is contained in:
708
content/post/6-ac-automation-home-assistant-node-red/index.fr.md
Normal file
708
content/post/6-ac-automation-home-assistant-node-red/index.fr.md
Normal file
@@ -0,0 +1,708 @@
|
||||
---
|
||||
slug: ac-automation-home-assistant-node-red
|
||||
title: Automatisation Complète de la Climatisation avec Home Assistant et Node-RED
|
||||
description: Comment j’automatise ma clim avec Home Assistant et Node-RED pour réagir à la température, l’humidité et à tous les évènements quotidiens.
|
||||
date: 2025-06-27
|
||||
draft: false
|
||||
tags:
|
||||
- home-automation
|
||||
- home-assistant
|
||||
- node-red
|
||||
categories:
|
||||
- automation
|
||||
---
|
||||
## Intro
|
||||
|
||||
Dans mon appartement, j’ai un système de climatisation Daikin, qui me permet de rafraîchir en été mais aussi de chauffer en hiver. Il est composé de 3 unités intérieures :
|
||||
- Salon
|
||||
- Chambre parentale
|
||||
- Couloir (juste en face de mon bureau et de la chambre de mon fils)
|
||||
|
||||
J’ai toujours trouvé ça pénible de devoir les allumer manuellement quand j’en avais besoin, et j’oubliais souvent de les éteindre ensuite, sans parler de la télécommande que je passais mon temps à chercher.
|
||||
|
||||
Et si je pouvais automatiser tout ça ? Après tout, j’utilise déjà Home Assistant pour piloter beaucoup de choses chez moi, alors contrôler la clim, ça me semble logique.
|
||||
|
||||
### Home Assistant
|
||||
|
||||
Home Assistant, c’est le cerveau de ma maison connectée. Il relie tous mes appareils (lumières, capteurs, volets, etc.) dans une interface unique. Sa vraie force, c’est la possibilité de créer des automatisations : si quelque chose se passe, alors fait ça. Des actions simples comme “allumer la lumière de la cuisine quand un mouvement est détecté” se mettent en place en quelques clics. Et pour des scénarios plus avancés, Home Assistant propose un système de scripts en YAML avec des conditions, des minuteries, des déclencheurs, et même du templating.
|
||||
|
||||
Mais dès qu’on commence à faire des automatisations un peu complexes, qui dépendent de plusieurs capteurs, d’horaires spécifiques ou de la présence de quelqu’un, ça devient vite difficile à lire. Les blocs de code YAML s’allongent, et on ne sait plus trop ce qui fait quoi, surtout quand on veut corriger un petit détail plusieurs semaines plus tard.
|
||||
|
||||
### Node-RED
|
||||
|
||||
C’est exactement pour ça que je suis passé à Node-RED. C’est un outil visuel qui permet de construire des logiques avec des blocs appelés “nœuds”, qu’on relie entre eux avec des flèches pour créer un **flow**. Chaque nœud fait une petite action : déclencher à une certaine heure, vérifier une condition, envoyer une commande à un appareil, etc. Au lieu d’écrire du YAML, on glisse les éléments, on les connecte, et c’est tout.
|
||||
|
||||
Node-RED ne remplace pas Home Assistant, il le renforce. Je ne détaillerai pas l'installation de Node-RED ni son intégration à HA, je l'ai fait il y a deux ans, mais de mémoire c'est assez simple.
|
||||
|
||||
## Ancien Workflow
|
||||
|
||||
J’avais déjà une solution plutôt efficace pour contrôler ma climatisation via Home Assistant et Node-RED, mais je voulais l’améliorer pour qu’elle prenne aussi en compte le taux d’humidité dans l’appartement. Mon workflow actuel, bien qu’il fonctionne, n’était pas vraiment évolutif et assez difficile à maintenir :
|
||||

|
||||
|
||||
## Nouveau Workflow
|
||||
|
||||
Plutôt que de bricoler ce flow existant, j’ai préféré repartir de zéro avec le même objectif : piloter le système de climatisation en prenant en compte tous les capteurs disponibles : thermomètres, humidité, capteurs d’ouverture, présence des occupants, moment de la journée, etc.
|
||||
|
||||
### Objectifs
|
||||
|
||||
L’idée est assez simple : ne plus avoir à penser à la climatisation, tout en restant efficace.
|
||||
|
||||
Mais concrètement, qu’est-ce que ça veut dire ? Je veux que la température et le taux d’humidité restent dans des valeurs confortables, que je sois présent ou non. Si j’ouvre les fenêtres, la clim doit s’arrêter. Si l’air est trop humide, je veux qu’il soit asséché. Si j’allume ou éteins manuellement la clim, je ne veux pas que ça écrase mes réglages. La nuit, je n’ai pas besoin de rafraîchir le salon et je veux aussi que le système soit silencieux, etc.
|
||||
|
||||
Pour m’aider à faire tout ça, j’utilise 4 [capteurs de température et d’humidité Aqara](https://eu.aqara.com/fr-eu/products/aqara-temperature-and-humidity-sensor), un dans chacune de mes pièces principales. J’utilise aussi quelques [capteurs d’ouverture Aqara](https://eu.aqara.com/fr-eu/products/aqara-door-and-window-sensor) pour savoir si une fenêtre est ouverte.
|
||||
|
||||
### Workflow
|
||||
|
||||
Laissez-moi vous présenter mon nouveau workflow de climatisation dans Node-RED, et vous expliquer en détail comment il fonctionne :
|
||||

|
||||
|
||||
#### #### 1. Capteurs de Température
|
||||
|
||||
Dans le premier nœud, j’ai regroupé tous les capteurs thermiques dans un seul `trigger state node`, en ajoutant non seulement la température mais aussi le taux d’humidité géré par chaque capteur. Ce nœud contient donc une liste de 8 entités (2 pour chaque capteur). À chaque fois qu’une de ces 8 valeurs change, le nœud est déclenché :
|
||||

|
||||
|
||||
Chacun de mes capteurs thermiques porte un nom de couleur en français, car ils ont tous un autocollant coloré pour les distinguer :
|
||||
- **Jaune** : Salon
|
||||
- **Bleu** : Chambre
|
||||
- **Rouge** : Bureau
|
||||
- **Vert** : Chambre de mon fils
|
||||
|
||||
Le deuxième nœud est un `function node` dont le rôle est de déterminer à quelle pièce appartient le capteur :
|
||||
```js
|
||||
const association = {
|
||||
"temperature_jaune": "salon",
|
||||
"temperature_bleu": "chambre",
|
||||
"temperature_rouge": "couloir",
|
||||
"temperature_vert": "couloir"
|
||||
};
|
||||
|
||||
// Match pattern like: sensor.temperature_rouge_temperature
|
||||
const match = msg.topic.match(/^sensor\.(.+)_(temperature|humidity)$/);
|
||||
|
||||
if (!match) {
|
||||
node.warn("Topic format not recognized: " + msg.topic);
|
||||
return null;
|
||||
}
|
||||
|
||||
msg.payload = {
|
||||
room: association[match[1]],
|
||||
sensor: match[1]
|
||||
};
|
||||
|
||||
return msg;
|
||||
```
|
||||
|
||||
Pour le dernier nœud, dans la majorité des cas, les capteurs envoient deux messages simultanés : l’un pour la température, l’autre pour l’humidité. J’ai donc ajouté un `join node` pour fusionner ces deux messages s’ils sont envoyés dans la même seconde :
|
||||

|
||||
|
||||
#### 2. Notification
|
||||
|
||||
Il peut arriver que les capteurs de température n’envoient plus d’état pendant un certain temps, pour une raison ou une autre. Dans ce cas, ils renvoient simplement leur dernière valeur connue, ce qui peut bloquer l’unité de climatisation associée.
|
||||
|
||||
La solution que j’ai trouvée efficace consiste à envoyer une notification si un capteur n’a pas transmis de nouvelle valeur depuis plus de 3 heures. En fonctionnement normal, chaque capteur envoie une mise à jour environ toutes les 15 minutes.
|
||||
|
||||
Le premier nœud est un `function node` un peu technique, qui crée une variable de flux comme minuteur pour chaque capteur. Une fois le délai écoulé, un message est envoyé au nœud suivant :
|
||||
```js
|
||||
const sensor = msg.payload.sensor;
|
||||
const timeoutKey = `watchdog_${sensor}`;
|
||||
const messages = {
|
||||
"temperature_jaune": {"title": "Température Salon", "message": "Capteur de température du salon semble hors service"},
|
||||
"temperature_bleu": {"title": "Température Chambre", "message": "Capteur de température de la chambre semble hors service"},
|
||||
"temperature_rouge": {"title": "Température Bureau", "message": "Capteur de température du bureau semble hors service"},
|
||||
"temperature_vert": {"title": "Température Raphaël", "message": "Capteur de température de Raphaël semble hors service"}
|
||||
};
|
||||
|
||||
// Clear existing timer
|
||||
const existing = flow.get(timeoutKey);
|
||||
if (existing) clearTimeout(existing);
|
||||
|
||||
// Set new timer
|
||||
const timer = setTimeout(() => {
|
||||
node.send({
|
||||
payload: `⚠️ No update from ${sensor} in 3 hours.`,
|
||||
sensor: sensor,
|
||||
title: messages[sensor]["title"],
|
||||
message: messages[sensor]["message"]
|
||||
});
|
||||
}, 3 * 60 * 60 * 1000); // 3 hours
|
||||
|
||||
flow.set(timeoutKey, timer);
|
||||
|
||||
return null; // Don't send anything now
|
||||
```
|
||||
|
||||
Le second nœud est un `call service node` qui envoie une notification sur mon téléphone Android avec les informations fournies :
|
||||

|
||||
|
||||
#### 3. Curseurs de Température
|
||||
|
||||
Pour pouvoir ajuster la température sans avoir à modifier tout le workflow, j’ai créé deux entrées (ou helper) Home Assistant, de type number, pour chaque unité de climatisation, ce qui me fait un total de 6 entrées :
|
||||

|
||||
|
||||
Ces valeurs représentent la température de base utilisée pour le calcul des seuils, en fonction des offsets que je détaillerai plus loin.
|
||||
|
||||
Le premier nœud est un `trigger state node` qui regroupe les 6 entités. Si je modifie l’une de ces valeurs, le nœud est déclenché :
|
||||

|
||||
|
||||
Le deuxième nœud est un `function node`, qui permet de déterminer la pièce concernée :
|
||||
```js
|
||||
const association = {
|
||||
"input_number.temp_ete_salon": "salon",
|
||||
"input_number.temp_hiver_salon": "salon",
|
||||
"input_number.temp_ete_chambre": "chambre",
|
||||
"input_number.temp_hiver_chambre": "chambre",
|
||||
"input_number.temp_ete_couloir": "couloir",
|
||||
"input_number.temp_hiver_couloir": "couloir"
|
||||
};
|
||||
|
||||
msg.payload = { room: association[msg.topic] };
|
||||
return msg;
|
||||
```
|
||||
|
||||
#### 4. Interrupteurs
|
||||
|
||||
Dans Home Assistant, j’utilise d’autres entrées, mais cette fois sous forme de booléens. Le plus important est celui dédié à la climatisation, qui me permet de désactiver manuellement tout le workflow. J’en ai d’autres qui sont automatisés, par exemple pour le moment de la journée ou la détection de présence à la maison.
|
||||
|
||||
J’utilise un autre `trigger state node` qui regroupe tous mes interrupteurs sous forme de booléens, y compris un bouton de test utilisé pour le débogage :
|
||||

|
||||
|
||||
Comme ces interrupteurs impactent tout l’appartement (et non une seule unité), le nœud suivant est un `change node` qui définit la valeur de la pièce à `partout` :
|
||||

|
||||
|
||||
#### 5. Fenêtres
|
||||
|
||||
Les derniers déclencheurs sont les fenêtres. Si j’ouvre ou ferme une fenêtre située près d’une unité, cela active le workflow. J’ai des capteurs d’ouverture sur certaines fenêtres, mais pour l’unité du couloir, j’utilise l’état des fenêtres Velux. Certaines pièces ayant plusieurs fenêtres, j’ai créé une entrée de type groupe pour les regrouper.
|
||||
|
||||
Le premier nœud est le dernier `trigger state node`. La valeur retournée est une string qu’il faudra ensuite convertir en booléen :
|
||||

|
||||
|
||||
Juste après, un autre `function node` permet d’identifier la pièce concernée :
|
||||
```js
|
||||
const association = {
|
||||
"binary_sensor.groupe_fenetre_salon": "salon",
|
||||
"binary_sensor.fenetre_chambre_contact": "chambre",
|
||||
"cover.groupe_fenetre_couloir": "couloir"
|
||||
};
|
||||
|
||||
msg.payload = {
|
||||
room: association[msg.topic]
|
||||
};
|
||||
return msg;
|
||||
```
|
||||
|
||||
#### 6. Fenêtre Watchdog
|
||||
|
||||
Quand j’ouvre une fenêtre, ce n’est pas forcément pour la laisser ouverte longtemps. Je peux simplement faire sortir le chat ou jeter un œil au portail. Je ne veux pas que la climatisation se coupe dès que j’ouvre une fenêtre. Pour contourner cela, j’ai mis en place un watchdog pour chaque unité, afin de retarder l’envoi du message pendant un certain temps.
|
||||
|
||||
Le premier nœud est un `switch node`. En fonction de la pièce transmise par le nœud précédent, il envoie le message au _watchdog_ correspondant :
|
||||

|
||||
|
||||
Viennent ensuite les _watchdogs_, des `trigger nodes`, qui retardent le message pendant un certain temps, et prolongent ce délai si un autre message est reçu entre-temps :
|
||||

|
||||
|
||||
#### 7. Climatisation Activée ?
|
||||
|
||||
Tous ces déclencheurs arrivent maintenant dans la chaîne de traitement, qui va déterminer ce que le système doit faire. Mais avant cela, on vérifie si l’automatisation est activée. J’ai ajouté ce kill switch au cas où, même si je l’utilise rarement.
|
||||
|
||||
Le premier nœud est un `delay node` qui régule le débit des messages entrants à 1 message par seconde :
|
||||

|
||||
|
||||
Le deuxième nœud est un `current state node` qui vérifie si le booléen `climatisation` est activé :
|
||||

|
||||
|
||||
#### 8. Configuration des pièces
|
||||
|
||||
L’idée ici est d’associer la configuration de la pièce au message. Chaque pièce a sa propre configuration : quelle unité est utilisée, quels capteurs sont associés, et surtout, dans quelles conditions elle doit s’allumer ou s’éteindre.
|
||||
|
||||
Les unités de climatisation disposent de 4 modes :
|
||||
- Refroidissement (Cool)
|
||||
- Déshumidification (Dry)
|
||||
- Ventilation (Fan)
|
||||
- Chauffage (Heat)
|
||||
|
||||
Pour déterminer quel mode utiliser, j’utilise des seuils pour chaque mode et la vitesse de ventilation, avec différents offsets selon la situation. Je peux ainsi définir un offset spécifique la nuit ou en cas d’absence. Je peux aussi définir un offset sur `disabled`, ce qui forcera l’arrêt de l’unité.
|
||||
|
||||
Le premier nœud est un `switch node`, basé sur la valeur `room`, qui oriente le message vers la configuration associée. Si la pièce est `partout`, le message est dupliqué vers les 3 configurations de pièce :
|
||||

|
||||
|
||||
Il est ensuite connecté à un `change node`, qui ajoute la configuration dans `room_config`. Voici un exemple avec la configuration du salon :
|
||||
```json
|
||||
{
|
||||
"threshold": {
|
||||
"cool": {
|
||||
"start": {
|
||||
"1": 1,
|
||||
"2": 1.5,
|
||||
"3": 2,
|
||||
"4": 2.5,
|
||||
"quiet": 0
|
||||
},
|
||||
"stop": -0.3,
|
||||
"target": -1,
|
||||
"offset": {
|
||||
"absent": 1,
|
||||
"vacances": "disabled",
|
||||
"fenetre": "disabled",
|
||||
"matin": "disabled",
|
||||
"jour": 0,
|
||||
"soir": 0,
|
||||
"nuit": "disabled"
|
||||
}
|
||||
},
|
||||
"dry": {
|
||||
"start": {
|
||||
"quiet": -1
|
||||
},
|
||||
"stop": -1.5,
|
||||
"offset": {
|
||||
"absent": "1.5",
|
||||
"vacances": "disabled",
|
||||
"fenetre": "disabled",
|
||||
"matin": "disabled",
|
||||
"jour": 0,
|
||||
"soir": 0,
|
||||
"nuit": "disabled"
|
||||
}
|
||||
},
|
||||
"fan_only": {
|
||||
"start": {
|
||||
"1": -0.3,
|
||||
"quiet": -0.5
|
||||
},
|
||||
"stop": -0.7,
|
||||
"offset": {
|
||||
"absent": "disabled",
|
||||
"vacances": "disabled",
|
||||
"fenetre": "disabled",
|
||||
"matin": "disabled",
|
||||
"jour": 0,
|
||||
"soir": 0,
|
||||
"nuit": "disabled"
|
||||
}
|
||||
},
|
||||
"heat": {
|
||||
"start": {
|
||||
"1": 0,
|
||||
"2": -1.5,
|
||||
"quiet": 0
|
||||
},
|
||||
"stop": 1,
|
||||
"target": 1,
|
||||
"offset": {
|
||||
"absent": -1.5,
|
||||
"vacances": -3,
|
||||
"fenetre": "disabled",
|
||||
"matin": 0,
|
||||
"jour": 0,
|
||||
"soir": 0,
|
||||
"nuit": -1.5
|
||||
}
|
||||
}
|
||||
},
|
||||
"unit": "climate.clim_salon",
|
||||
"timer": "timer.minuteur_clim_salon",
|
||||
"window": "binary_sensor.groupe_fenetre_salon",
|
||||
"thermometre": "sensor.temperature_jaune_temperature",
|
||||
"humidity": "sensor.temperature_jaune_humidity",
|
||||
"temp_ete": "input_number.temp_ete_salon",
|
||||
"temp_hiver": "input_number.temp_hiver_salon"
|
||||
}
|
||||
```
|
||||
|
||||
#### #### 9. Calcul
|
||||
|
||||
Maintenant que le message contient la configuration de la pièce, on entre dans la phase de calcul. On dispose du nom de l’unité de climatisation, des capteurs associés, de la température de base souhaitée et de l’offset à appliquer. À partir de ces données, on récupère les états actuels et on effectue les calculs.
|
||||
|
||||
Le premier nœud est un `delay node` qui régule le débit des messages entrants, car le bloc précédent a potentiellement généré trois messages si toutes les pièces sont concernées.
|
||||
|
||||
Le deuxième nœud est le plus important du workflow, un `function node` qui remplit plusieurs rôles :
|
||||
|
||||
- Récupère les états des capteurs depuis Home Assistant
|
||||
- Calcule les seuils des modes à partir des offsets
|
||||
- Désactive certains modes si les conditions sont remplies
|
||||
- Injecte les valeurs dans le `payload`
|
||||
```js
|
||||
// --- Helper: Get Home Assistant state by entity ID ---
|
||||
function getState(entityId) {
|
||||
return global.get("homeassistant.homeAssistant.states")[entityId]?.state;
|
||||
}
|
||||
|
||||
// --- Determine current time period based on sensors ---
|
||||
const periods = ["jour", "soir", "nuit", "matin"];
|
||||
msg.payload.period = periods.find(p => getState(`binary_sensor.${p}`) === 'on') || 'unknown';
|
||||
|
||||
// --- Determine presence status (absent = inverse of presence) ---
|
||||
const vacances = getState("input_boolean.absent");
|
||||
const absent = getState("input_boolean.presence") === 'on' ? 'off' : 'on';
|
||||
|
||||
/**
|
||||
* Recursively adds the base temperature and offset to all numeric start values in a threshold config
|
||||
*/
|
||||
function applyOffsetToThresholds(threshold, baseTemp, globalOffset) {
|
||||
for (const [key, value] of Object.entries(threshold)) {
|
||||
if (key === "offset") continue;
|
||||
|
||||
if (typeof value === 'object') {
|
||||
applyOffsetToThresholds(value, baseTemp, globalOffset);
|
||||
} else {
|
||||
threshold[key] += baseTemp + globalOffset;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* Calculates the global offset for a mode, based on presence, vacation, window, and time of day
|
||||
*/
|
||||
function calculateGlobalOffset(offsets, modeName, windowState, disabledMap) {
|
||||
let globalOffset = 0;
|
||||
|
||||
for (const [key, offsetValue] of Object.entries(offsets)) {
|
||||
let conditionMet = false;
|
||||
|
||||
if (key === msg.payload.period) conditionMet = true;
|
||||
else if (key === "absent" && absent === 'on') conditionMet = true;
|
||||
else if (key === "vacances" && vacances === 'on') conditionMet = true;
|
||||
else if ((key === "fenetre" || key === "window") && windowState === 'on') conditionMet = true;
|
||||
|
||||
if (conditionMet) {
|
||||
if (offsetValue === 'disabled') {
|
||||
disabledMap[modeName] = true;
|
||||
return 0; // Mode disabled immediately
|
||||
}
|
||||
|
||||
globalOffset += parseFloat(offsetValue);
|
||||
}
|
||||
}
|
||||
|
||||
return globalOffset;
|
||||
}
|
||||
|
||||
/**
|
||||
* Main logic: compute thresholds for the specified room using the provided config
|
||||
*/
|
||||
const cfg = msg.payload.room_config;
|
||||
const room = msg.payload.room;
|
||||
|
||||
// Normalize window sensor state
|
||||
const rawWindow = getState(cfg.window);
|
||||
const window = rawWindow === 'open' ? 'on' : rawWindow === 'closed' ? 'off' : rawWindow;
|
||||
|
||||
// Gather temperatures
|
||||
const temps = cfg.thermometre.split(',')
|
||||
.map(id => parseFloat(getState(id)))
|
||||
.filter(v => !isNaN(v));
|
||||
|
||||
const temp_avg = temps.reduce((a, b) => a + b, 0) / temps.length;
|
||||
const temp_min = Math.min(...temps);
|
||||
const temp_max = Math.max(...temps);
|
||||
|
||||
// Gather humidity
|
||||
const humidities = cfg.humidity.split(',')
|
||||
.map(id => parseFloat(getState(id)))
|
||||
.filter(v => !isNaN(v));
|
||||
|
||||
const humidity_avg = humidities.reduce((a, b) => a + b, 0) / humidities.length;
|
||||
const humidity_min = Math.min(...humidities);
|
||||
const humidity_max = Math.max(...humidities);
|
||||
|
||||
// Get base temps
|
||||
const temp_ete = parseFloat(getState(cfg.temp_ete));
|
||||
const temp_hiver = parseFloat(getState(cfg.temp_hiver));
|
||||
|
||||
// Process modes
|
||||
const { threshold } = cfg;
|
||||
const modes = ["cool", "dry", "fan_only", "heat"];
|
||||
const disabled = {};
|
||||
|
||||
for (const mode of modes) {
|
||||
const baseTemp = (mode === "heat") ? temp_hiver : temp_ete;
|
||||
const globalOffset = calculateGlobalOffset(threshold[mode].offset, mode, window, disabled);
|
||||
|
||||
applyOffsetToThresholds(threshold[mode], baseTemp, globalOffset);
|
||||
}
|
||||
|
||||
// Final message
|
||||
msg.payload = {
|
||||
...msg.payload,
|
||||
unit: cfg.unit,
|
||||
timer: cfg.timer,
|
||||
threshold,
|
||||
window,
|
||||
temp: {
|
||||
min: temp_min,
|
||||
max: temp_max,
|
||||
avg: Math.round(temp_avg * 100) / 100
|
||||
},
|
||||
humidity: {
|
||||
min: humidity_min,
|
||||
max: humidity_max,
|
||||
avg: Math.round(humidity_avg * 100) / 100
|
||||
},
|
||||
disabled
|
||||
};
|
||||
|
||||
return msg;
|
||||
```
|
||||
|
||||
Le troisième nœud est un `filter node`, qui ignore les messages suivants ayant un contenu similaire :
|
||||

|
||||
|
||||
Le quatrième nœud vérifie si un verrou est actif à l’aide d’un `current state node`. On regarde si le minuteur associé à l’unité est inactif. Si ce n’est pas le cas, le message est ignoré :
|
||||

|
||||
|
||||
Le dernier nœud est un autre `current state node` qui permet de récupérer l’état actuel de l’unité et ses propriétés :
|
||||

|
||||
|
||||
#### 10. État Cible
|
||||
|
||||
Après les calculs, il s'agit maintenant de déterminer quel doit être le mode cible, quelle action effectuer pour converger vers ce mode à partir de l’état actuel, et le cas échéant, quelle vitesse de ventilation utiliser pour ce mode.
|
||||
|
||||
Les trois nœuds suivants sont des `function nodes`. Le premier détermine le mode cible à adopter parmi : `off`, `cool`, `dry`, `fan_only` et `heat` :
|
||||
```js
|
||||
const minHumidityThreshold = 52;
|
||||
const maxHumidityThreshold = 57;
|
||||
|
||||
// Helper: check if mode can be activated or stopped
|
||||
function isModeEligible(mode, temps, humidity, thresholds, currentMode) {
|
||||
const isCurrent = (mode === currentMode);
|
||||
const threshold = thresholds[mode];
|
||||
|
||||
if (msg.payload.disabled?.[mode]) return false;
|
||||
|
||||
// Determine which temperature to use for start/stop:
|
||||
// start: temp.max (except heat uses temp.min)
|
||||
// stop: temp.avg
|
||||
let tempForCheckStart;
|
||||
if (mode === "heat") {
|
||||
tempForCheckStart = temps.min; // heat start uses min temp
|
||||
} else {
|
||||
tempForCheckStart = temps.max; // others start use max temp
|
||||
}
|
||||
const tempForCheckStop = temps.avg;
|
||||
|
||||
// Dry mode also depends on humidity thresholds
|
||||
// humidity max for start, humidity avg for stop
|
||||
let humidityForCheckStart = humidity.max;
|
||||
let humidityForCheckStop = humidity.avg;
|
||||
|
||||
// For heat mode (inverted logic)
|
||||
if (mode === "heat") {
|
||||
if (!isCurrent) {
|
||||
const minStart = Math.max(...Object.values(threshold.start));
|
||||
return tempForCheckStart < minStart;
|
||||
} else {
|
||||
return tempForCheckStop < threshold.stop;
|
||||
}
|
||||
}
|
||||
|
||||
// For dry mode (humidity-dependent)
|
||||
if (mode === "dry") {
|
||||
// Skip if humidity too low
|
||||
if (humidityForCheckStart <= (isCurrent ? minHumidityThreshold : maxHumidityThreshold)) return false;
|
||||
|
||||
const minStart = Math.min(...Object.values(threshold.start));
|
||||
if (!isCurrent) {
|
||||
return tempForCheckStart >= minStart;
|
||||
} else {
|
||||
return tempForCheckStop >= threshold.stop;
|
||||
}
|
||||
}
|
||||
|
||||
// For cool and fan_only
|
||||
if (!isCurrent) {
|
||||
const minStart = Math.min(...Object.values(threshold.start));
|
||||
return tempForCheckStart >= minStart;
|
||||
} else {
|
||||
return tempForCheckStop >= threshold.stop;
|
||||
}
|
||||
}
|
||||
|
||||
// --- Main logic ---
|
||||
const { threshold, temp, humidity, current_mode, disabled } = msg.payload;
|
||||
|
||||
const priority = ["cool", "dry", "fan_only", "heat"];
|
||||
let target_mode = "off";
|
||||
|
||||
// Loop through priority list and stop at the first eligible mode
|
||||
for (const mode of priority) {
|
||||
if (isModeEligible(mode, temp, humidity, threshold, current_mode)) {
|
||||
target_mode = mode;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
msg.payload.target_mode = target_mode;
|
||||
|
||||
if (target_mode === "cool" || target_mode === "heat") {
|
||||
msg.payload.set_temp = true;
|
||||
}
|
||||
|
||||
return msg;
|
||||
```
|
||||
|
||||
Le second compare le mode actuel avec le mode cible et choisit l’action à effectuer :
|
||||
- **check** : le mode actuel est identique au mode cible.
|
||||
- **start** : l’unité est éteinte, mais un mode actif est requis.
|
||||
- **change** : l’unité est allumée, mais le mode cible est différent du mode actuel (et n’est pas `off`).
|
||||
- **stop** : l’unité est allumée mais doit être arrêtée.
|
||||
```js
|
||||
let action = "check"; // default if both are same
|
||||
|
||||
if (msg.payload.current_mode === "off" && msg.payload.target_mode !== "off") {
|
||||
action = "start";
|
||||
} else if (msg.payload.current_mode !== "off" && msg.payload.target_mode !== "off" && msg.payload.current_mode !== msg.payload.target_mode) {
|
||||
action = "change";
|
||||
} else if (msg.payload.current_mode !== "off" && msg.payload.target_mode === "off") {
|
||||
action = "stop";
|
||||
}
|
||||
|
||||
msg.payload.action = action;
|
||||
return msg;
|
||||
```
|
||||
|
||||
Le dernier nœud détermine la vitesse de ventilation appropriée pour le mode cible, en fonction des seuils définis :
|
||||
```js
|
||||
// Function to find the appropriate speed key based on temperature and mode
|
||||
function findSpeed(thresholdStart, temperature, mode) {
|
||||
let closestSpeed = 'quiet';
|
||||
let closestTemp = mode === 'heat' ? Infinity : -Infinity;
|
||||
|
||||
for (const speedKey in thresholdStart) {
|
||||
if (speedKey !== 'quiet') {
|
||||
const tempValue = thresholdStart[speedKey];
|
||||
if (mode === 'heat') {
|
||||
if (tempValue >= temperature && tempValue <= closestTemp) {
|
||||
closestSpeed = speedKey;
|
||||
closestTemp = tempValue;
|
||||
}
|
||||
} else { // cool, fan_only
|
||||
if (tempValue <= temperature && tempValue >= closestTemp) {
|
||||
closestSpeed = speedKey;
|
||||
closestTemp = tempValue;
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
return closestSpeed;
|
||||
}
|
||||
|
||||
if (msg.payload.target_mode && msg.payload.target_mode !== "off" && msg.payload.target_mode !== "dry") {
|
||||
const modeData = msg.payload.threshold[msg.payload.target_mode];
|
||||
if (modeData && modeData.start) {
|
||||
if (msg.payload.target_mode === "heat") {
|
||||
msg.payload.speed = findSpeed(modeData.start, msg.payload.temp.min, 'heat');
|
||||
} else {
|
||||
msg.payload.speed = findSpeed(modeData.start, msg.payload.temp.max, 'cool');
|
||||
}
|
||||
} else {
|
||||
node.error("Invalid mode data or missing 'start' thresholds", msg);
|
||||
}
|
||||
} else {
|
||||
// No need for speed in 'off' or 'dry' modes
|
||||
msg.payload.speed = null;
|
||||
}
|
||||
|
||||
return msg;
|
||||
```
|
||||
|
||||
#### 11. Choix de l'Action
|
||||
|
||||
En fonction de l’action à effectuer, le `switch node` va router le message vers le bon chemin :
|
||||

|
||||
|
||||
#### 12. Démarrage
|
||||
|
||||
Lorsque l’action est `start`, il faut d’abord allumer l’unité. Cela prend entre 20 et 40 secondes selon le modèle, et une fois démarrée, l’unité est verrouillée pendant un court laps de temps pour éviter les messages suivants.
|
||||
|
||||
Le premier nœud est un `call service node` utilisant le service `turn_on` sur l’unité de climatisation :
|
||||

|
||||
|
||||
Le second nœud est un autre `call service node` qui va démarrer un minuteur de verrouillage (lock timer) pour cette unité pendant 45 secondes :
|
||||

|
||||
|
||||
Le dernier est un `delay node` de 5 secondes, pour laisser le temps à l’intégration Daikin de Home Assistant de refléter le nouvel état.
|
||||
|
||||
---
|
||||
|
||||
#### 13. Changement
|
||||
|
||||
L’action `change` est utilisée pour passer d’un mode à un autre, mais aussi juste après l’allumage.
|
||||
|
||||
Le premier nœud est un `call service node` utilisant le service `set_hvac_mode` sur l’unité de climatisation :
|
||||

|
||||
|
||||
Le nœud suivant est un `delay node` de 5 secondes.
|
||||
|
||||
Le dernier vérifie, avec un `switch node`, si la température cible doit être définie. Cela n’est nécessaire que pour les modes `cool` et `heat` :
|
||||

|
||||
|
||||
---
|
||||
|
||||
#### 14. Définir la Température Cible
|
||||
|
||||
La température cible est uniquement pertinente pour les modes `cool` et `heat`. Avec une climatisation classique, vous définissez une température à atteindre — c’est exactement ce qu’on fait ici. Mais comme chaque unité utilise son propre capteur interne pour vérifier cette température, je ne leur fais pas vraiment confiance. Si la température cible est déjà atteinte selon l’unité, elle ne soufflera plus du tout.
|
||||
|
||||
Le premier nœud est un autre `call service node` utilisant le service `set_temperature` :
|
||||

|
||||
|
||||
Encore une fois, ce nœud est suivi d’un `delay node` de 5 secondes.
|
||||
|
||||
#### 15. Vérification
|
||||
|
||||
L’action `check` est utilisée presque tout le temps. Elle consiste uniquement à vérifier et comparer la vitesse de ventilation souhaitée, et à la modifier si nécessaire.
|
||||
|
||||
Le premier nœud est un `switch node` qui vérifie si la valeur `speed` est définie :
|
||||

|
||||
|
||||
Le deuxième est un autre `switch node` qui compare la valeur `speed` avec la vitesse actuelle :
|
||||

|
||||
|
||||
Enfin, le dernier nœud est un `call service node` utilisant le service `set_fan_mode` pour définir la vitesse du ventilateur :
|
||||

|
||||
|
||||
#### 16. Arrêt
|
||||
|
||||
Lorsque l’action est `stop`, l’unité de climatisation est simplement arrêtée.
|
||||
|
||||
Le premier nœud est un `call service node` utilisant le service `turn_off` :
|
||||

|
||||
|
||||
Le deuxième nœud est un autre `call service node` qui va démarrer le minuteur de verrouillage de cette unité pour 45 secondes.
|
||||
|
||||
#### 17. Intervention Manuelle
|
||||
|
||||
Parfois, pour une raison ou une autre, on souhaite utiliser la climatisation manuellement. Dans ce cas, on ne veut pas que le flux Node-RED vienne écraser notre réglage manuel, du moins pendant un certain temps.
|
||||
Node-RED utilise son propre utilisateur dans Home Assistant, donc si une unité change d’état sans cet utilisateur, c’est qu’une intervention manuelle a eu lieu.
|
||||
|
||||
Le premier nœud est un `trigger state node`, qui envoie un message dès qu’une unité AC change d’état :
|
||||

|
||||
|
||||
Le deuxième est un `function node` qui associe l’unité avec son minuteur :
|
||||
```js
|
||||
const association = {
|
||||
"climate.clim_salon": "timer.minuteur_clim_salon",
|
||||
"climate.clim_chambre": "timer.minuteur_clim_chambre",
|
||||
"climate.clim_couloir": "timer.minuteur_clim_couloir"
|
||||
};
|
||||
|
||||
msg.payload = association[msg.topic];
|
||||
return msg;
|
||||
```
|
||||
|
||||
Le troisième est un `switch node` qui laisse passer le message uniquement si le `user_id` **n’est pas** celui de Node-RED :
|
||||

|
||||
|
||||
Le quatrième est un autre `switch node` qui vérifie que le champ `user_id` **est bien défini** :
|
||||

|
||||
|
||||
Enfin, le dernier nœud est un `call service node` utilisant le service `start` sur le minuteur de l’unité, avec sa durée par défaut (60 minutes) :
|
||||

|
||||
|
||||
## TL;DR
|
||||
|
||||
Avec cette configuration, mon système de climatisation est entièrement automatisé, du refroidissement en été au chauffage en hiver, tout en gardant un œil sur le taux d’humidité.
|
||||
|
||||
Cela m’a demandé pas mal de réflexion, d’ajustements et de tests, mais au final je suis vraiment satisfait du résultat. C’est pourquoi je le partage ici, pour vous donner des idées sur ce qu’on peut faire en domotique.
|
||||
|
||||
Si vous pensez que certaines choses pourraient être faites autrement, n’hésitez pas à me contacter pour en discuter ou me proposer de nouvelles idées !
|
||||
|
||||
700
content/post/6-ac-automation-home-assistant-node-red/index.md
Normal file
700
content/post/6-ac-automation-home-assistant-node-red/index.md
Normal file
@@ -0,0 +1,700 @@
|
||||
---
|
||||
slug: ac-automation-home-assistant-node-red
|
||||
title: Full AC Automation with Home Assistant and Node-RED
|
||||
description: How I automate my AC with Home Assistant and Node-RED to react to temperature, humidity and all daily events.
|
||||
date: 2025-06-27
|
||||
draft: false
|
||||
tags:
|
||||
- home-automation
|
||||
- home-assistant
|
||||
- node-red
|
||||
categories:
|
||||
- automation
|
||||
---
|
||||
## Intro
|
||||
|
||||
In my apartment I have a Daikin air conditioning system, to cool it down in summer, but also warm it up in winter. It is composed of 3 indoor units:
|
||||
- Living room
|
||||
- Master bedroom
|
||||
- Hallway (in front of my office and my kid's room)
|
||||
|
||||
I always find it boring to have to turn them on when I needed, I forgot to turn them off when I should and I was constantly chasing the remote.
|
||||
|
||||
What if I could automate it? After all, I already use Home Assistant to control many devices at home, controlling the AC seems natural to me.
|
||||
|
||||
### Home Assistant
|
||||
|
||||
Home Assistant is the brain of my smart home. It connects all my devices (lights, sensors, shutters, etc.) under a single interface. What makes it so powerful is the ability to create automations: if something happens, then do something else. Simple things like “turn on the kitchen light when the motion sensor is triggered” are a breeze. For more advanced workflows, it offers YAML-based scripts with conditions, delays, triggers, and templates.
|
||||
|
||||
That said, once automations start getting more complex, like reacting to multiple sensors, time ranges, or presence detection, they can quickly turn into long, hard-to-follow blocks of code. It’s easy to lose track of what does what, especially when you want to tweak just one small part weeks later.
|
||||
|
||||
### Node-RED
|
||||
|
||||
That’s exactly why I turned to Node-RED. It’s a visual tool that lets you build logic using blocks called “nodes”, which you connect with wires to create flows. Each node performs a small task: trigger at a certain time, check a condition, send a command to a device, etc. Instead of writing YAML, you just drag, drop, and connect.
|
||||
|
||||
Node-RED does not replace Home Assistant, it empowers it. I won't cover the installation of Node-RED neither the integration in HA, I've done that 2 years ago, but for that I remember, this is quite straightforward.
|
||||
|
||||
## Previous Workflow
|
||||
|
||||
I was already having a good solution to control my AC from Home Assistant with Node-RED, but I wanted to enhance it to also handle the humidity level at home. My current workflow, despite being functional, was not really scalable and quite hard to maintain:
|
||||

|
||||
|
||||
## New Workflow
|
||||
|
||||
Instead of tweaking this workflow, I created a new one from scratch, with the same goal in mind: control the AC system by taking into account all available sensors: thermometers, humidity, door sensors, occupant presence, time of day, etc.
|
||||
|
||||
### Objectives
|
||||
|
||||
The idea is pretty simple: do not having to think about AC while still being efficient.
|
||||
|
||||
That being said, what does that mean? I want to keep the temperature and humidity level in check, whenever I'm here or not. If I open the windows, it should stop blowing. If it is too wet, I want to dry the air. If I turn the AC on or off manually, I don't want it to overwrite my setting. If it's night, I don't need to cool my living-room and I want it quiet, etc.
|
||||
|
||||
To help me achieve that, I'm using 4 [Aqara temperature and humidity sensors](https://eu.aqara.com/en-eu/products/aqara-temperature-and-humidity-sensor), one in each of my main room. I'm also using some [Aqara door sensors](https://eu.aqara.com/en-eu/products/aqara-door-and-window-sensor, to detect it windows are open.
|
||||
|
||||
### Workflow
|
||||
|
||||
Let me introduce my new AC workflow within Node-RED and explain what it does in detail:
|
||||

|
||||
|
||||
#### 1. Temperature Sensors
|
||||
|
||||
In the first node, I combined all the temperature sensors together in one `trigger state node`, but I also added humidity levels in addition to the temperature, managed by the sensor. The node then contains 8 entities in a list (2 for each of my sensor). Each time one value change out of these 8 entities, the node is triggered:
|
||||

|
||||
|
||||
Each of my temperature sensors are named with a color in French, because each has its own color sticker to distinguish them:
|
||||
- **Jaune**: Living room
|
||||
- **Bleu**: Bedroom
|
||||
- **Rouge**: Office
|
||||
- **Vert**: Kid's bedroom
|
||||
|
||||
The second node is a `function node` which has the role the determine the room of the sensor (`function node` is written in **JavaScript**):
|
||||
```js
|
||||
const association = {
|
||||
"temperature_jaune": "salon",
|
||||
"temperature_bleu": "chambre",
|
||||
"temperature_rouge": "couloir",
|
||||
"temperature_vert": "couloir"
|
||||
};
|
||||
|
||||
// Match pattern like: sensor.temperature_rouge_temperature
|
||||
const match = msg.topic.match(/^sensor\.(.+)_(temperature|humidity)$/);
|
||||
|
||||
if (!match) {
|
||||
node.warn("Topic format not recognized: " + msg.topic);
|
||||
return null;
|
||||
}
|
||||
|
||||
msg.payload = {
|
||||
room: association[match[1]],
|
||||
sensor: match[1]
|
||||
};
|
||||
|
||||
return msg;
|
||||
```
|
||||
|
||||
For the last node, most of the time, the sensors will send two messages at the same time, one containing the temperature value and the other, the humidity level. I added a `join node` to combined the two messages if they are sent within the same second:
|
||||

|
||||
|
||||
#### 2. Notification
|
||||
|
||||
It can happen that the temperature sensors are not sending states anymore for some reason. In that case, they will always return their last value, which would lock the associated AC unit.
|
||||
|
||||
The workaround I found effective is to send a notification if the sensor did not send a new value in the last 3 hours. In normal situation, the sensor send an update approximately every 15 minutes.
|
||||
|
||||
The first node is a `function node` a bit tricky which will generate flow variable as timer for each sensor. When the timeout is reach, it sends a message to the next node:
|
||||
```js
|
||||
const sensor = msg.payload.sensor;
|
||||
const timeoutKey = `watchdog_${sensor}`;
|
||||
const messages = {
|
||||
"temperature_jaune": {"title": "Température Salon", "message": "Capteur de température du salon semble hors service"},
|
||||
"temperature_bleu": {"title": "Température Chambre", "message": "Capteur de température de la chambre semble hors service"},
|
||||
"temperature_rouge": {"title": "Température Bureau", "message": "Capteur de température du bureau semble hors service"},
|
||||
"temperature_vert": {"title": "Température Raphaël", "message": "Capteur de température de Raphaël semble hors service"}
|
||||
};
|
||||
|
||||
// Clear existing timer
|
||||
const existing = flow.get(timeoutKey);
|
||||
if (existing) clearTimeout(existing);
|
||||
|
||||
// Set new timer
|
||||
const timer = setTimeout(() => {
|
||||
node.send({
|
||||
payload: `⚠️ No update from ${sensor} in 3 hours.`,
|
||||
sensor: sensor,
|
||||
title: messages[sensor]["title"],
|
||||
message: messages[sensor]["message"]
|
||||
});
|
||||
}, 3 * 60 * 60 * 1000); // 3 hours
|
||||
|
||||
flow.set(timeoutKey, timer);
|
||||
|
||||
return null; // Don't send anything now
|
||||
```
|
||||
|
||||
The second node is a `call service node` which send a notification on my Android device with the value given:
|
||||

|
||||
|
||||
#### 3. Temperature Sliders
|
||||
|
||||
To have a control over the temperature without having to change the workflow, I created two Home Assistant helper, as number, which I can adjust for each unit, giving me 6 helpers in total:
|
||||

|
||||
|
||||
These values are the base temperature used for the calculation of the threshold, depending off the offset which I will detail further.
|
||||
|
||||
The first node is a `trigger state node`, with all 6 entities combined. If I change one value, the node is triggered:
|
||||

|
||||
|
||||
The second node is a `function node`, to determine the room affected:
|
||||
```js
|
||||
const association = {
|
||||
"input_number.temp_ete_salon": "salon",
|
||||
"input_number.temp_hiver_salon": "salon",
|
||||
"input_number.temp_ete_chambre": "chambre",
|
||||
"input_number.temp_hiver_chambre": "chambre",
|
||||
"input_number.temp_ete_couloir": "couloir",
|
||||
"input_number.temp_hiver_couloir": "couloir"
|
||||
};
|
||||
|
||||
msg.payload = { room: association[msg.topic] };
|
||||
return msg;
|
||||
```
|
||||
|
||||
#### 4. Toggles
|
||||
|
||||
In Home Assistant, I'm using other helper but as boolean, the most important is the AC one, where I can manually disable the whole workflow. I have other which are automated, for the time of the day or for detect presence at home.
|
||||
|
||||
I have another `trigger state node` with all my toggles as boolean, including a test button, for debug purpose:
|
||||

|
||||
|
||||
As toggles affect the whole apartment and not a single unit, the next node is a `change node`, which set the room value to `partout` (everywhere):
|
||||

|
||||
|
||||
#### 5. Windows
|
||||
|
||||
The last triggers are my windows, if I open or close a window next to my unit, it triggers the workflow. I have door sensor for some of my doors, but for the hallway unit, I'm using the Velux windows state. Some rooms have more than one, I created a group helper for them.
|
||||
|
||||
The first node is the last `trigger state node`, the returned value is a string which I will have to convert later into boolean:
|
||||

|
||||
|
||||
Connected to it, again a `function node` to select the affect room:
|
||||
```js
|
||||
const association = {
|
||||
"binary_sensor.groupe_fenetre_salon": "salon",
|
||||
"binary_sensor.fenetre_chambre_contact": "chambre",
|
||||
"cover.groupe_fenetre_couloir": "couloir"
|
||||
};
|
||||
|
||||
msg.payload = {
|
||||
room: association[msg.topic]
|
||||
};
|
||||
return msg;
|
||||
```
|
||||
|
||||
#### 6. Window Watchdog
|
||||
|
||||
When I open a window, it is not necessarily to let it open for a long time. I could just let the cat out or having a look at my portal. I don't want my AC tuned off as soon as open it. To workaround that I created a watchdog for each unit, to delay the message for some time.
|
||||
|
||||
The first node is a `switch node`, based on the room given by the previous node, it will send the message to the associated watchdog:
|
||||

|
||||
|
||||
After are the watchdogs, `trigger nodes`, which will delay the message by some time and extend the delay if another message if received:
|
||||

|
||||
|
||||
#### 7. AC Enabled ?
|
||||
|
||||
All these triggers are now entering the computing pipeline, to determine what the system must do with the action. But before, it is checking if the automation is even enabled. I add this kill switch, just in case, but I rarely use it anyway.
|
||||
|
||||
The first node is a `delay node` which regulate the rate of every incoming messages to 1 per second:
|
||||

|
||||
|
||||
The second node is a `current state node` which checks if the `climatisation` boolean is enabled:
|
||||

|
||||
#### 8. Room Configuration
|
||||
|
||||
The idea here is to attach the configuration of the room to the message. Each room have their own configuration, which unit is used, which sensors and more importantly, when should they be turned on and off.
|
||||
|
||||
AC units have 4 mode which can be used:
|
||||
- Cool
|
||||
- Dry
|
||||
- Fan
|
||||
- Heat
|
||||
|
||||
To determine which mode should be used, I'm using threshold for each mode and unit fan's speed, with different offset depending the situation. I can then define a offset during the night or when I'm away. I can also set the offset to `disabled`, which will force the unit to shut down.
|
||||
|
||||
The first node is a `switch node`, based on the `room` value, which will route the message to the associated room configuration. When the room is `partout` (everywhere), the message is split to all 3 room configuration:
|
||||

|
||||
|
||||
It is connected to a `change node` which will attach the configuration to the `room_config`, here an example with the living-room configuration:
|
||||
```json
|
||||
{
|
||||
"threshold": {
|
||||
"cool": {
|
||||
"start": {
|
||||
"1": 1,
|
||||
"2": 1.5,
|
||||
"3": 2,
|
||||
"4": 2.5,
|
||||
"quiet": 0
|
||||
},
|
||||
"stop": -0.3,
|
||||
"target": -1,
|
||||
"offset": {
|
||||
"absent": 1,
|
||||
"vacances": "disabled",
|
||||
"fenetre": "disabled",
|
||||
"matin": "disabled",
|
||||
"jour": 0,
|
||||
"soir": 0,
|
||||
"nuit": "disabled"
|
||||
}
|
||||
},
|
||||
"dry": {
|
||||
"start": {
|
||||
"quiet": -1
|
||||
},
|
||||
"stop": -1.5,
|
||||
"offset": {
|
||||
"absent": "1.5",
|
||||
"vacances": "disabled",
|
||||
"fenetre": "disabled",
|
||||
"matin": "disabled",
|
||||
"jour": 0,
|
||||
"soir": 0,
|
||||
"nuit": "disabled"
|
||||
}
|
||||
},
|
||||
"fan_only": {
|
||||
"start": {
|
||||
"1": -0.3,
|
||||
"quiet": -0.5
|
||||
},
|
||||
"stop": -0.7,
|
||||
"offset": {
|
||||
"absent": "disabled",
|
||||
"vacances": "disabled",
|
||||
"fenetre": "disabled",
|
||||
"matin": "disabled",
|
||||
"jour": 0,
|
||||
"soir": 0,
|
||||
"nuit": "disabled"
|
||||
}
|
||||
},
|
||||
"heat": {
|
||||
"start": {
|
||||
"1": 0,
|
||||
"2": -1.5,
|
||||
"quiet": 0
|
||||
},
|
||||
"stop": 1,
|
||||
"target": 1,
|
||||
"offset": {
|
||||
"absent": -1.5,
|
||||
"vacances": -3,
|
||||
"fenetre": "disabled",
|
||||
"matin": 0,
|
||||
"jour": 0,
|
||||
"soir": 0,
|
||||
"nuit": -1.5
|
||||
}
|
||||
}
|
||||
},
|
||||
"unit": "climate.clim_salon",
|
||||
"timer": "timer.minuteur_clim_salon",
|
||||
"window": "binary_sensor.groupe_fenetre_salon",
|
||||
"thermometre": "sensor.temperature_jaune_temperature",
|
||||
"humidity": "sensor.temperature_jaune_humidity",
|
||||
"temp_ete": "input_number.temp_ete_salon",
|
||||
"temp_hiver": "input_number.temp_hiver_salon"
|
||||
}
|
||||
```
|
||||
|
||||
#### 9. Computation
|
||||
|
||||
Now that the message has the room configuration attached, we are entering in the computation pipeline. We have the AC unit name, the sensor names, the desired base temperature and the offset to apply. From these values, we will fetch the current state and do the maths.
|
||||
|
||||
The first node is another `delay node` which regulate the rate of incoming messages, because the previous block could have created 3 messages in all rooms are targeted.
|
||||
|
||||
The second is the most important node of the workflow, a `function node` that has multiple tasks:
|
||||
- Fetch sensor state for Home Assistant
|
||||
- Calculate mode thresholds with given offset
|
||||
- Disable modes if conditions are met
|
||||
- Inject these values in the payload
|
||||
```js
|
||||
// --- Helper: Get Home Assistant state by entity ID ---
|
||||
function getState(entityId) {
|
||||
return global.get("homeassistant.homeAssistant.states")[entityId]?.state;
|
||||
}
|
||||
|
||||
// --- Determine current time period based on sensors ---
|
||||
const periods = ["jour", "soir", "nuit", "matin"];
|
||||
msg.payload.period = periods.find(p => getState(`binary_sensor.${p}`) === 'on') || 'unknown';
|
||||
|
||||
// --- Determine presence status (absent = inverse of presence) ---
|
||||
const vacances = getState("input_boolean.absent");
|
||||
const absent = getState("input_boolean.presence") === 'on' ? 'off' : 'on';
|
||||
|
||||
/**
|
||||
* Recursively adds the base temperature and offset to all numeric start values in a threshold config
|
||||
*/
|
||||
function applyOffsetToThresholds(threshold, baseTemp, globalOffset) {
|
||||
for (const [key, value] of Object.entries(threshold)) {
|
||||
if (key === "offset") continue;
|
||||
|
||||
if (typeof value === 'object') {
|
||||
applyOffsetToThresholds(value, baseTemp, globalOffset);
|
||||
} else {
|
||||
threshold[key] += baseTemp + globalOffset;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* Calculates the global offset for a mode, based on presence, vacation, window, and time of day
|
||||
*/
|
||||
function calculateGlobalOffset(offsets, modeName, windowState, disabledMap) {
|
||||
let globalOffset = 0;
|
||||
|
||||
for (const [key, offsetValue] of Object.entries(offsets)) {
|
||||
let conditionMet = false;
|
||||
|
||||
if (key === msg.payload.period) conditionMet = true;
|
||||
else if (key === "absent" && absent === 'on') conditionMet = true;
|
||||
else if (key === "vacances" && vacances === 'on') conditionMet = true;
|
||||
else if ((key === "fenetre" || key === "window") && windowState === 'on') conditionMet = true;
|
||||
|
||||
if (conditionMet) {
|
||||
if (offsetValue === 'disabled') {
|
||||
disabledMap[modeName] = true;
|
||||
return 0; // Mode disabled immediately
|
||||
}
|
||||
|
||||
globalOffset += parseFloat(offsetValue);
|
||||
}
|
||||
}
|
||||
|
||||
return globalOffset;
|
||||
}
|
||||
|
||||
/**
|
||||
* Main logic: compute thresholds for the specified room using the provided config
|
||||
*/
|
||||
const cfg = msg.payload.room_config;
|
||||
const room = msg.payload.room;
|
||||
|
||||
// Normalize window sensor state
|
||||
const rawWindow = getState(cfg.window);
|
||||
const window = rawWindow === 'open' ? 'on' : rawWindow === 'closed' ? 'off' : rawWindow;
|
||||
|
||||
// Gather temperatures
|
||||
const temps = cfg.thermometre.split(',')
|
||||
.map(id => parseFloat(getState(id)))
|
||||
.filter(v => !isNaN(v));
|
||||
|
||||
const temp_avg = temps.reduce((a, b) => a + b, 0) / temps.length;
|
||||
const temp_min = Math.min(...temps);
|
||||
const temp_max = Math.max(...temps);
|
||||
|
||||
// Gather humidity
|
||||
const humidities = cfg.humidity.split(',')
|
||||
.map(id => parseFloat(getState(id)))
|
||||
.filter(v => !isNaN(v));
|
||||
|
||||
const humidity_avg = humidities.reduce((a, b) => a + b, 0) / humidities.length;
|
||||
const humidity_min = Math.min(...humidities);
|
||||
const humidity_max = Math.max(...humidities);
|
||||
|
||||
// Get base temps
|
||||
const temp_ete = parseFloat(getState(cfg.temp_ete));
|
||||
const temp_hiver = parseFloat(getState(cfg.temp_hiver));
|
||||
|
||||
// Process modes
|
||||
const { threshold } = cfg;
|
||||
const modes = ["cool", "dry", "fan_only", "heat"];
|
||||
const disabled = {};
|
||||
|
||||
for (const mode of modes) {
|
||||
const baseTemp = (mode === "heat") ? temp_hiver : temp_ete;
|
||||
const globalOffset = calculateGlobalOffset(threshold[mode].offset, mode, window, disabled);
|
||||
|
||||
applyOffsetToThresholds(threshold[mode], baseTemp, globalOffset);
|
||||
}
|
||||
|
||||
// Final message
|
||||
msg.payload = {
|
||||
...msg.payload,
|
||||
unit: cfg.unit,
|
||||
timer: cfg.timer,
|
||||
threshold,
|
||||
window,
|
||||
temp: {
|
||||
min: temp_min,
|
||||
max: temp_max,
|
||||
avg: Math.round(temp_avg * 100) / 100
|
||||
},
|
||||
humidity: {
|
||||
min: humidity_min,
|
||||
max: humidity_max,
|
||||
avg: Math.round(humidity_avg * 100) / 100
|
||||
},
|
||||
disabled
|
||||
};
|
||||
|
||||
return msg;
|
||||
```
|
||||
|
||||
The third node is a `filter node`, which drops subsequent messages with similar payload:
|
||||

|
||||
|
||||
The fourth node checks if any lock is set, with a `current state node`, we verify if the timer associated to the unit is idle. If not, the message is discarded:
|
||||

|
||||
|
||||
The last node is another `current state node` which will fetch the unit state and properties:
|
||||

|
||||
|
||||
#### 10. Target State
|
||||
|
||||
After the computation, we want to determine what should be the target mode, what action to do to converge from the current mode and, if apply, what should be the fan's speed for that mode.
|
||||
|
||||
All three nodes are `function nodes`, the first one decides what should be the target mode, between: `off`, `cool`, `dry`, `fan_only` and `heat`:
|
||||
```js
|
||||
const minHumidityThreshold = 52;
|
||||
const maxHumidityThreshold = 57;
|
||||
|
||||
// Helper: check if mode can be activated or stopped
|
||||
function isModeEligible(mode, temps, humidity, thresholds, currentMode) {
|
||||
const isCurrent = (mode === currentMode);
|
||||
const threshold = thresholds[mode];
|
||||
|
||||
if (msg.payload.disabled?.[mode]) return false;
|
||||
|
||||
// Determine which temperature to use for start/stop:
|
||||
// start: temp.max (except heat uses temp.min)
|
||||
// stop: temp.avg
|
||||
let tempForCheckStart;
|
||||
if (mode === "heat") {
|
||||
tempForCheckStart = temps.min; // heat start uses min temp
|
||||
} else {
|
||||
tempForCheckStart = temps.max; // others start use max temp
|
||||
}
|
||||
const tempForCheckStop = temps.avg;
|
||||
|
||||
// Dry mode also depends on humidity thresholds
|
||||
// humidity max for start, humidity avg for stop
|
||||
let humidityForCheckStart = humidity.max;
|
||||
let humidityForCheckStop = humidity.avg;
|
||||
|
||||
// For heat mode (inverted logic)
|
||||
if (mode === "heat") {
|
||||
if (!isCurrent) {
|
||||
const minStart = Math.max(...Object.values(threshold.start));
|
||||
return tempForCheckStart < minStart;
|
||||
} else {
|
||||
return tempForCheckStop < threshold.stop;
|
||||
}
|
||||
}
|
||||
|
||||
// For dry mode (humidity-dependent)
|
||||
if (mode === "dry") {
|
||||
// Skip if humidity too low
|
||||
if (humidityForCheckStart <= (isCurrent ? minHumidityThreshold : maxHumidityThreshold)) return false;
|
||||
|
||||
const minStart = Math.min(...Object.values(threshold.start));
|
||||
if (!isCurrent) {
|
||||
return tempForCheckStart >= minStart;
|
||||
} else {
|
||||
return tempForCheckStop >= threshold.stop;
|
||||
}
|
||||
}
|
||||
|
||||
// For cool and fan_only
|
||||
if (!isCurrent) {
|
||||
const minStart = Math.min(...Object.values(threshold.start));
|
||||
return tempForCheckStart >= minStart;
|
||||
} else {
|
||||
return tempForCheckStop >= threshold.stop;
|
||||
}
|
||||
}
|
||||
|
||||
// --- Main logic ---
|
||||
const { threshold, temp, humidity, current_mode, disabled } = msg.payload;
|
||||
|
||||
const priority = ["cool", "dry", "fan_only", "heat"];
|
||||
let target_mode = "off";
|
||||
|
||||
// Loop through priority list and stop at the first eligible mode
|
||||
for (const mode of priority) {
|
||||
if (isModeEligible(mode, temp, humidity, threshold, current_mode)) {
|
||||
target_mode = mode;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
msg.payload.target_mode = target_mode;
|
||||
|
||||
if (target_mode === "cool" || target_mode === "heat") {
|
||||
msg.payload.set_temp = true;
|
||||
}
|
||||
|
||||
return msg;
|
||||
```
|
||||
|
||||
The second compares the current and target node and pick which action to take:
|
||||
- **check**: current and target are the same.
|
||||
- **start**: the AC unit is currently off, but the target is different.
|
||||
- **change**: the AC unit is on, the target mode is different, but not `off`.
|
||||
- **stop**: the AC unit is on and it is required to stop it.
|
||||
```js
|
||||
let action = "check"; // default if both are same
|
||||
|
||||
if (msg.payload.current_mode === "off" && msg.payload.target_mode !== "off") {
|
||||
action = "start";
|
||||
} else if (msg.payload.current_mode !== "off" && msg.payload.target_mode !== "off" && msg.payload.current_mode !== msg.payload.target_mode) {
|
||||
action = "change";
|
||||
} else if (msg.payload.current_mode !== "off" && msg.payload.target_mode === "off") {
|
||||
action = "stop";
|
||||
}
|
||||
|
||||
msg.payload.action = action;
|
||||
return msg;
|
||||
```
|
||||
|
||||
The last node determines the fan's speed of the target mode based on thresholds:
|
||||
```js
|
||||
// Function to find the appropriate speed key based on temperature and mode
|
||||
function findSpeed(thresholdStart, temperature, mode) {
|
||||
let closestSpeed = 'quiet';
|
||||
let closestTemp = mode === 'heat' ? Infinity : -Infinity;
|
||||
|
||||
for (const speedKey in thresholdStart) {
|
||||
if (speedKey !== 'quiet') {
|
||||
const tempValue = thresholdStart[speedKey];
|
||||
if (mode === 'heat') {
|
||||
if (tempValue >= temperature && tempValue <= closestTemp) {
|
||||
closestSpeed = speedKey;
|
||||
closestTemp = tempValue;
|
||||
}
|
||||
} else { // cool, fan_only
|
||||
if (tempValue <= temperature && tempValue >= closestTemp) {
|
||||
closestSpeed = speedKey;
|
||||
closestTemp = tempValue;
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
return closestSpeed;
|
||||
}
|
||||
|
||||
if (msg.payload.target_mode && msg.payload.target_mode !== "off" && msg.payload.target_mode !== "dry") {
|
||||
const modeData = msg.payload.threshold[msg.payload.target_mode];
|
||||
if (modeData && modeData.start) {
|
||||
if (msg.payload.target_mode === "heat") {
|
||||
msg.payload.speed = findSpeed(modeData.start, msg.payload.temp.min, 'heat');
|
||||
} else {
|
||||
msg.payload.speed = findSpeed(modeData.start, msg.payload.temp.max, 'cool');
|
||||
}
|
||||
} else {
|
||||
node.error("Invalid mode data or missing 'start' thresholds", msg);
|
||||
}
|
||||
} else {
|
||||
// No need for speed in 'off' or 'dry' modes
|
||||
msg.payload.speed = null;
|
||||
}
|
||||
|
||||
return msg;
|
||||
```
|
||||
|
||||
#### 11. Action Switch
|
||||
|
||||
Based on the action to take, the `switch node` will route the message accordingly:
|
||||

|
||||
|
||||
#### 12. Start
|
||||
|
||||
When the action is `start`, we first need to turn the unit online, while this takes between 20 to 40 seconds depending on the unit model, it is also locking the unit for a short period for future messages.
|
||||
|
||||
The first node is a `call service node` using the `turn_on` service on the AC unit:
|
||||

|
||||
|
||||
The second node is another `call service node` which will start the lock timer of this unit for 45 seconds:
|
||||

|
||||
|
||||
The last one is a `delay node` of 5 seconds, to give the time to the Home Assistant Daikin integration to resolve the new state.
|
||||
|
||||
#### 13. Change
|
||||
|
||||
The `change` action is used to change from one mode to another, but also used right after the start action.
|
||||
|
||||
The first node is a `call service node` using `the set_hvac_mode` service on the AC unit:
|
||||

|
||||
|
||||
The following node is another delay of 5 seconds.
|
||||
|
||||
The last one verify with a `switch node` if the target temperature needs to be set, this is only required for the modes `cool` and `heat`:
|
||||

|
||||
|
||||
#### 14. Set Target Temperature
|
||||
|
||||
The target temperature is only relevant for `cool` and `heat` mode, when you use a normal AC unit, you define a temperature to reach. This is exactly what is defined here. But because each unit is using its own internal sensor to verify, I don't trust it. If the value is already reached, the unit won't blow anything.
|
||||
|
||||
The first node is another `call service node` using the `set_temperature` service:
|
||||

|
||||
|
||||
Again, this node is followed by a `delay node` of 5 seconds
|
||||
|
||||
#### 15. Check
|
||||
|
||||
The `check` action is almost used everytime, it is actually only checks and compare the desired fan speed, it changes the fan speed if needed.
|
||||
|
||||
The first node is a `switch node` which verify if the `speed` is defined:
|
||||

|
||||
|
||||
The second is another `switch node` to compare the `speed` value with the current speed:
|
||||

|
||||
|
||||
Finally the last node is a `call service node` using the `set_fan_mode` to set the fan speed:
|
||||

|
||||
|
||||
#### 16. Stop
|
||||
|
||||
When the `action` is stop, the AC unit is simply turned off
|
||||
|
||||
The first node is a `call service noded` using the service `turn_off`:
|
||||

|
||||
|
||||
The second node is another `call service node` which will start the lock timer of this unit for 45 seconds
|
||||
|
||||
#### 17. Manual Intervention
|
||||
|
||||
Sometime, for some reason, we want to use the AC manually. When we do, we don't want the workflow to change our manual setting, at least for some time. Node-RED is using its own user in Home Assistant, so when an AC unit change state without this user, this was manually done.
|
||||
|
||||
The first node is a `trigger state node`, which will send a message when any AC unit is changing state:
|
||||

|
||||
|
||||
The second is a `function node` which willassociate the unit with its timer:
|
||||
```js
|
||||
const association = {
|
||||
"climate.clim_salon": "timer.minuteur_clim_salon",
|
||||
"climate.clim_chambre": "timer.minuteur_clim_chambre",
|
||||
"climate.clim_couloir": "timer.minuteur_clim_couloir"
|
||||
};
|
||||
|
||||
msg.payload = association[msg.topic];
|
||||
return msg;
|
||||
```
|
||||
|
||||
The third is a `switch node` that will let through the message when the user_id is not the Node-RED user's one:
|
||||

|
||||
|
||||
The fourth is another `switch node` which checks if there are any `user_id`:
|
||||

|
||||
|
||||
Lastly, the final node is a `call service node` using `start` service on the unit's timer with its default duration (60 minutes):
|
||||

|
||||
|
||||
## TL;DR
|
||||
|
||||
With this setup, my AC system is fully automated, from cooling in summer to warming in winter, while keeping in check the humidity level.
|
||||
|
||||
This required quite a lot of thinking, tweaking and testing, but finally I'm now very happy with the results, that's why I'm sharing it with you, to give you some ideas about what you can do in home automation.
|
||||
|
||||
If you think I could have done things differently, please reach out to me to discuss about it, do not hesitate to share your ideas as well!
|
||||
Reference in New Issue