Auto-update blog content from Obsidian: 2026-04-29 19:59:52
Some checks failed
Blog Deployment / Check-Rebuild (push) Successful in 8s
Blog Deployment / Build (push) Successful in 31s
Blog Deployment / Deploy-Staging (push) Successful in 9s
Blog Deployment / Test-Staging (push) Failing after 3s
Blog Deployment / Merge (push) Has been skipped
Blog Deployment / Deploy-Production (push) Has been skipped
Blog Deployment / Test-Production (push) Has been skipped
Blog Deployment / Clean (push) Has been skipped
Blog Deployment / Notify (push) Successful in 3s
Some checks failed
Blog Deployment / Check-Rebuild (push) Successful in 8s
Blog Deployment / Build (push) Successful in 31s
Blog Deployment / Deploy-Staging (push) Successful in 9s
Blog Deployment / Test-Staging (push) Failing after 3s
Blog Deployment / Merge (push) Has been skipped
Blog Deployment / Deploy-Production (push) Has been skipped
Blog Deployment / Test-Production (push) Has been skipped
Blog Deployment / Clean (push) Has been skipped
Blog Deployment / Notify (push) Successful in 3s
This commit is contained in:
@@ -0,0 +1,281 @@
|
||||
---
|
||||
slug: opnsense-virtualization-highly-available
|
||||
title: Construire un Cluster OPNsense Hautement Disponible sur Proxmox VE
|
||||
description: Une preuve de concept montrant comment virtualiser OPNsense sur Proxmox VE, configurer la haute disponibilité avec CARP et pfSync, et gérer une seule IP WAN.
|
||||
date: 2025-09-29
|
||||
draft: false
|
||||
tags:
|
||||
- opnsense
|
||||
- proxmox
|
||||
- high-availability
|
||||
categories:
|
||||
- homelab
|
||||
---
|
||||
## Intro
|
||||
|
||||
J’ai récemment rencontré mon premier vrai problème, ma box **OPNsense** physique a planté à cause d’un _kernel panic_. J’ai détaillé ce qu'il s'est passé dans [cet article]({{< ref "post/10-opnsense-crash-disk-panic" >}}).
|
||||
|
||||
Cette panne m’a fait repenser mon installation. Un seul pare-feu est un point de défaillance unique, donc pour améliorer la résilience j’ai décidé de prendre une nouvelle approche : **virtualiser OPNsense**.
|
||||
|
||||
Évidemment, faire tourner une seule VM ne suffirait pas. Pour obtenir une vraie redondance, il me faut deux instances OPNsense en **Haute Disponibilité**, l’une active et l’autre en attente.
|
||||
|
||||
Avant de déployer ça sur mon réseau, j’ai voulu valider l’idée dans mon homelab. Dans cet article, je vais détailler la preuve de concept : déployer deux VM OPNsense dans un cluster **Proxmox VE** et les configurer pour fournir un pare-feu hautement disponible.
|
||||
|
||||
---
|
||||
## Infrastructure Actuelle
|
||||
|
||||
Au sommet de mon installation, mon modem FAI, une _Freebox_ en mode bridge, relié directement à l’interface `igc0` de ma box OPNsense, servant d’interface **WAN**. Sur `igc1`, le **LAN** est connecté à mon switch principal via un port trunk, avec le VLAN 1 comme VLAN natif pour mon réseau de management.
|
||||
|
||||
Ce switch relie également mes trois nœuds Proxmox, chacun sur un port trunk avec le même VLAN natif. Chaque nœud dispose de deux cartes réseau : une pour le trafic général, et l’autre dédiée au réseau de stockage Ceph, connecté à un switch séparé de 2,5 Gbps.
|
||||
|
||||
Depuis le crash d’OPNsense, j’ai simplifié l’architecture en supprimant le lien LACP, qui n’apportait pas de réelle valeur :
|
||||

|
||||
|
||||
Jusqu’à récemment, le réseau Proxmox de mon cluster était très basique : chaque nœud était configuré individuellement sans véritable logique commune. Cela a changé après la découverte du SDN Proxmox, qui m’a permis de centraliser les définitions de VLAN sur l’ensemble du cluster. J’ai décrit cette étape dans [cet article]({{< ref "post/11-proxmox-cluster-networking-sdn" >}}).
|
||||
|
||||
---
|
||||
## Preuve de Concept
|
||||
|
||||
Place au lab. Voici les étapes principales :
|
||||
1. Ajouter quelques VLANs dans mon homelab
|
||||
2. Créer un faux routeur FAI
|
||||
3. Construire deux VMs OPNsense
|
||||
4. Configurer la haute disponibilité
|
||||
5. Tester la bascule
|
||||
|
||||

|
||||
|
||||
### Ajouter des VLANs dans mon homelab
|
||||
|
||||
Pour cette expérimentation, je crée trois nouveaux VLANs :
|
||||
- **VLAN 101** : _POC WAN_
|
||||
- **VLAN 102** : _POC LAN_
|
||||
- **VLAN 103** : _POC pfSync_
|
||||
|
||||
Dans l’interface Proxmox, je vais dans `Datacenter` > `SDN` > `VNets` et je clique sur `Create` :
|
||||

|
||||
|
||||
Une fois les trois VLANs créés, j’applique la configuration.
|
||||
|
||||
J’ajoute ensuite ces trois VLANs dans mon contrôleur UniFi. Ici, seul l’ID et le nom sont nécessaires, le contrôleur se charge de les propager via les trunks connectés à mes nœuds Proxmox VE.
|
||||
|
||||
### Créer une VM “Fausse Box FAI”
|
||||
|
||||
Pour simuler mon modem FAI actuel, j’ai créé une VM appelée `fake-freebox`. Cette VM route le trafic entre les réseaux _POC WAN_ et _Lab_, et fait tourner un serveur DHCP qui ne délivre qu’un seul bail, exactement comme ma vraie Freebox en mode bridge.
|
||||
|
||||
Cette VM dispose de 2 cartes réseau, que je configure avec Netplan :
|
||||
- `eth0` (_POC WAN_ VLAN 101) : adresse IP statique `10.101.0.254/24`
|
||||
- `enp6s19` (Lab VLAN 66) : adresse IP obtenue en DHCP depuis mon routeur OPNsense actuel, en amont
|
||||
```yaml
|
||||
network:
|
||||
version: 2
|
||||
ethernets:
|
||||
eth0:
|
||||
addresses:
|
||||
- 10.101.0.254/24
|
||||
enp6s19:
|
||||
dhcp4: true
|
||||
```
|
||||
|
||||
J’active ensuite le routage IP pour permettre à cette VM de router le trafic :
|
||||
```bash
|
||||
echo "net.ipv4.ip_forward=1" | sudo tee -a /etc/sysctl.conf
|
||||
sudo sysctl -p
|
||||
```
|
||||
|
||||
Puis je configure du masquage (NAT) afin que les paquets sortant via le réseau Lab ne soient pas rejetés par mon OPNsense actuel :
|
||||
```bash
|
||||
sudo iptables -t nat -A POSTROUTING -o enp6s19 -j MASQUERADE
|
||||
sudo apt install iptables-persistent -y
|
||||
sudo netfilter-persistent save
|
||||
```
|
||||
|
||||
J’installe `dnsmasq` comme serveur DHCP léger :
|
||||
```bash
|
||||
sudo apt install dnsmasq -y
|
||||
```
|
||||
|
||||
Dans `/etc/dnsmasq.conf`, je configure un bail unique (`10.101.0.150`) et je pointe le DNS vers mon OPNsense actuel, sur le VLAN _Lab_ :
|
||||
```
|
||||
interface=eth0
|
||||
bind-interfaces
|
||||
dhcp-range=10.101.0.150,10.101.0.150,255.255.255.0,12h
|
||||
dhcp-option=3,10.101.0.254 # default gateway = this VM
|
||||
dhcp-option=6,192.168.66.1 # DNS server
|
||||
```
|
||||
|
||||
Je redémarre le service `dnsmasq` pour appliquer la configuration :
|
||||
```bash
|
||||
sudo systemctl restart dnsmasq
|
||||
```
|
||||
|
||||
La VM `fake-freebox` est maintenant prête à fournir du DHCP sur le VLAN 101, avec un seul bail disponible.
|
||||
|
||||
### Construire les VMs OPNsense
|
||||
|
||||
Je commence par télécharger l’ISO d’OPNsense et je l’upload sur un de mes nœuds Proxmox :
|
||||

|
||||
|
||||
#### Création de la VM
|
||||
|
||||
Je crée la première VM `poc-opnsense-1` avec les paramètres suivants :
|
||||
- Type d’OS : Linux (même si OPNsense est basé sur FreeBSD)
|
||||
- Type de machine : `q35`
|
||||
- BIOS : `OVMF (UEFI)`, stockage EFI sur mon pool Ceph
|
||||
- Disque : 20 Go sur Ceph
|
||||
- CPU/RAM : 2 vCPU, 2 Go de RAM
|
||||
- Cartes réseau :
|
||||
1. VLAN 101 (_POC WAN_)
|
||||
2. VLAN 102 (_POC LAN_)
|
||||
3. VLAN 103 (_POC pfSync_)
|
||||

|
||||
|
||||
ℹ️ Avant de la démarrer, je clone cette VM pour préparer la seconde : `poc-opnsense-2`
|
||||
|
||||
Au premier démarrage, je tombe sur une erreur “access denied”. Pour corriger, j’entre dans le BIOS, **Device Manager > Secure Boot Configuration**, je décoche _Attempt Secure Boot_ et je redémarre :
|
||||

|
||||
|
||||
#### Installation d’OPNsense
|
||||
|
||||
La VM démarre sur l’ISO, je ne touche à rien jusqu’à l’écran de login :
|
||||

|
||||
|
||||
Je me connecte avec `installer` / `opnsense` et je lance l’installateur. Je sélectionne le disque QEMU de 20 Go comme destination et je démarre l’installation :
|
||||

|
||||
|
||||
Une fois terminé, je retire l’ISO du lecteur et je redémarre la machine.
|
||||
|
||||
#### Configuration de Base d’OPNsense
|
||||
|
||||
Au redémarrage, je me connecte avec `root` / `opnsense` et j’arrive au menu CLI :
|
||||

|
||||
|
||||
Avec l’option 1, je réassigne les interfaces :
|
||||

|
||||
|
||||
L’interface WAN récupère bien `10.101.0.150/24` depuis la `fake-freebox`. Je configure le LAN sur `10.102.0.2/24` et j’ajoute un pool DHCP de `10.102.0.10` à `10.102.0.99` :
|
||||

|
||||
|
||||
✅ La première VM est prête, je reproduis l’opération pour la seconde OPNsense `poc-opnsense-2`, qui aura l’IP `10.102.0.3`.
|
||||
|
||||
### Configurer OPNsense en Haute Disponibilité
|
||||
|
||||
Avec les deux VMs OPNsense opérationnelles, il est temps de passer à la configuration via le WebGUI. Pour y accéder, j’ai connecté une VM Windows au VLAN _POC LAN_ et ouvert l’IP de l’OPNsense sur le port 443 :
|
||||

|
||||
|
||||
#### Ajouter l’Interface pfSync
|
||||
|
||||
La troisième carte réseau (`vtnet2`) est assignée à l’interface _pfSync_. Ce réseau dédié permet aux deux firewalls de synchroniser leurs états via le VLAN _POC pfSync_ :
|
||||

|
||||
|
||||
J’active l’interface sur chaque instance et je leur attribue une IP statique :
|
||||
- **poc-opnsense-1** : `10.103.0.2/24`
|
||||
- **poc-opnsense-2** : `10.103.0.3/24`
|
||||
|
||||
Puis, j’ajoute une règle firewall sur chaque nœud pour autoriser tout le trafic provenant de ce réseau sur l’interface _pfSync_ :
|
||||

|
||||
|
||||
#### Configurer la Haute Disponibilité
|
||||
|
||||
Direction `System` > `High Availability` > `Settings`.
|
||||
- Sur le master (`poc-opnsense-1`), je configure les `General Settings` et les `Synchronization Settings`.
|
||||
- Sur le backup (`poc-opnsense-2`), seuls les `General Settings` suffisent (on ne veut pas qu’il écrase la config du master).
|
||||

|
||||
|
||||
Une fois appliqué, je vérifie la synchro dans l’onglet `Status` :
|
||||

|
||||
|
||||
#### Créer une IP Virtuelle
|
||||
|
||||
Pour fournir une passerelle partagée aux clients, je crée une IP virtuelle (VIP) en **CARP** (Common Address Redundancy Protocol) sur l’interface LAN. L’IP est portée par le nœud actif et bascule automatiquement en cas de failover.
|
||||
|
||||
Menu : `Interfaces` > `Virtual IPs` > `Settings` :
|
||||

|
||||
|
||||
Je réplique ensuite la config depuis `System > High Availability > Status` avec le bouton `Synchronize and reconfigure all`.
|
||||
|
||||
Sur `Interfaces > Virtual IPs > Status`, le master affiche la VIP en `MASTER` et le backup en `BACKUP`.
|
||||
|
||||
#### Reconfigurer le DHCP
|
||||
|
||||
Pour la HA, il faut adapter le DHCP. Comme **Dnsmasq** ne supporte pas la synchro des baux, chaque instance doit répondre indépendamment.
|
||||
|
||||
Sur le master :
|
||||
- `Services` > `Dnsmasq DNS & DHCP` > `General` : cocher `Disable HA sync`
|
||||
- `DHCP ranges` : cocher aussi `Disable HA sync`
|
||||
- `DHCP options` : ajouter l’option `router [3]` avec la valeur `10.102.0.1` (VIP LAN)
|
||||
- `DHCP options` : cloner la règle pour `dns-server [6]` vers la même VIP.
|
||||

|
||||
|
||||
Sur le backup :
|
||||
- `Services` > `Dnsmasq DNS & DHCP` > `General` : cocher `Disable HA sync`
|
||||
- Régler `DHCP reply delay` à `5` secondes (laisser la priorité au master)
|
||||
- `DHCP ranges` : définir un autre pool, plus petit (`10.102.0.200 -> 220`).
|
||||
|
||||
Ainsi, seules les **options** DHCP sont synchronisées, les plages restant distinctes.
|
||||
|
||||
#### Interface WAN
|
||||
|
||||
Mon modem FAI n’attribue qu’une seule IP en DHCP, je ne veux pas que mes 2 VMs entrent en compétition. Pour gérer ça :
|
||||
1. Dans Proxmox, je copie l’adresse MAC de `net0` (WAN) de `poc-opnsense-1` et je l’applique à `poc-opnsense-2`. Ainsi, le bail DHCP est partagé.
|
||||
⚠️ Si les deux VMs activent la même MAC en même temps, cela provoque des conflits ARP et peut casser le réseau. Seul le MASTER doit activer son WAN.
|
||||
2. Un hook event CARP procure la possibilité de lancer des scripts. J’ai déployé ce [script Gist](https://gist.github.com/spali/2da4f23e488219504b2ada12ac59a7dc#file-10-wancarp) dans `/usr/local/etc/rc.syshook.d/carp/10-wan` sur les deux nœuds. Ce script active le WAN uniquement sur le MASTER.
|
||||
```php
|
||||
#!/usr/local/bin/php
|
||||
<?php
|
||||
|
||||
require_once("config.inc");
|
||||
require_once("interfaces.inc");
|
||||
require_once("util.inc");
|
||||
require_once("system.inc");
|
||||
|
||||
$subsystem = !empty($argv[1]) ? $argv[1] : '';
|
||||
$type = !empty($argv[2]) ? $argv[2] : '';
|
||||
|
||||
if ($type != 'MASTER' && $type != 'BACKUP') {
|
||||
log_error("Carp '$type' event unknown from source '{$subsystem}'");
|
||||
exit(1);
|
||||
}
|
||||
|
||||
if (!strstr($subsystem, '@')) {
|
||||
log_error("Carp '$type' event triggered from wrong source '{$subsystem}'");
|
||||
exit(1);
|
||||
}
|
||||
|
||||
$ifkey = 'wan';
|
||||
|
||||
if ($type === "MASTER") {
|
||||
log_error("enable interface '$ifkey' due CARP event '$type'");
|
||||
$config['interfaces'][$ifkey]['enable'] = '1';
|
||||
write_config("enable interface '$ifkey' due CARP event '$type'", false);
|
||||
interface_configure(false, $ifkey, false, false);
|
||||
} else {
|
||||
log_error("disable interface '$ifkey' due CARP event '$type'");
|
||||
unset($config['interfaces'][$ifkey]['enable']);
|
||||
write_config("disable interface '$ifkey' due CARP event '$type'", false);
|
||||
interface_configure(false, $ifkey, false, false);
|
||||
}
|
||||
```
|
||||
|
||||
### Tester le Failover
|
||||
|
||||
Passons aux tests !
|
||||
|
||||
OPNsense propose un _CARP Maintenance Mode_. Avec le master actif, seul lui avait son WAN monté. En activant le mode maintenance, les rôles basculent : le master devient backup, son WAN est désactivé et celui du backup est activé :
|
||||

|
||||
|
||||
Pendant mes pings vers l’extérieur, aucune perte de paquets au moment du basculement.
|
||||
|
||||
Ensuite, j’ai simulé un crash en éteignant le master. Le backup a pris le relais de façon transparente, seulement un paquet perdu, et grâce à la synchro des états, même ma session SSH est restée ouverte. 🎉
|
||||
|
||||
## Conclusion
|
||||
|
||||
Cette preuve de concept démontre qu’il est possible de faire tourner **OPNsense en haute dispo sous Proxmox VE**, même avec une seule IP WAN. Les briques nécessaires :
|
||||
- Segmentation VLAN
|
||||
- Réseau dédié pfSync
|
||||
- IP virtuelle partagée (CARP)
|
||||
- Script pour gérer l’interface WAN
|
||||
|
||||
Le résultat est à la hauteur : failover transparent, synchro des états, et connexions actives qui survivent à un crash. Le point le plus délicat reste la gestion du bail WAN, mais le hook CARP règle ce problème.
|
||||
|
||||
🚀 Prochaine étape : préparer un nouveau cluster OPNsense HA sur Proxmox en vue de remplacer complètement ma box physique actuel. Restez à l'écoute !
|
||||
@@ -0,0 +1,283 @@
|
||||
---
|
||||
slug: opnsense-virtualization-highly-available
|
||||
title: Build a Highly Available OPNsense Cluster on Proxmox VE
|
||||
description: A proof of concept showing how to virtualize OPNsense on Proxmox VE, configure high availability with CARP and pfSync and handle a single WAN IP.
|
||||
date: 2025-09-29
|
||||
draft: false
|
||||
tags:
|
||||
- opnsense
|
||||
- proxmox
|
||||
- high-availability
|
||||
categories:
|
||||
- homelab
|
||||
---
|
||||
## Intro
|
||||
|
||||
I recently encountered my first real problem, my physical **OPNsense** box crashed because of a kernel panic, I've detailed what happened in that [post]({{< ref "post/10-opnsense-crash-disk-panic" >}}).
|
||||
|
||||
That failure made me rethink my setup. A unique firewall is a single point of failure, so to improve resilience I decided to take a new approach: **virtualize OPNsense**.
|
||||
|
||||
Of course, just running one VM wouldn’t be enough. To get real redundancy, I need two OPNsense instances in **High Availability**, with one active and the other standing by.
|
||||
|
||||
Before rolling this out in my network, I wanted to demonstrate the idea in my homelab. In this post, I’ll walk through the proof of concept: deploying two OPNsense VMs inside a **Proxmox VE** cluster and configuring them to provide a highly available firewall.
|
||||
|
||||
---
|
||||
## Current Infrastructure
|
||||
|
||||
On top of my setup, my ISP modem, a *Freebox* in bridge mode, connects directly to the `igc0` interface of my OPNsense box, serving as the **WAN**. On `igc1`, the **LAN** is linked to my main switch using a trunk port, with VLAN 1 as the native VLAN for my management network.
|
||||
|
||||
The switch also connects my three Proxmox nodes, each on trunk ports with the same native VLAN. Every node has two NICs: one for general networking and the other dedicated to the Ceph storage network, which runs through a separate 2.5 Gbps switch.
|
||||
|
||||
Since the OPNsense crash, I’ve simplified things by removing the LACP link, it wasn’t adding real value:
|
||||

|
||||
|
||||
|
||||
Until recently, Proxmox networking on my cluster was very basic: each node was configured individually with no real overlay logic. That changed after I explored Proxmox SDN, where I centralized VLAN definitions across the cluster. I described that step in [this article]({{< ref "post/11-proxmox-cluster-networking-sdn" >}}).
|
||||
|
||||
---
|
||||
## Proof of Concept
|
||||
|
||||
Time to move into the lab. Here are the main steps:
|
||||
1. Add some VLANs in my Homelab
|
||||
2. Create Fake ISP router
|
||||
3. Build two OPNsense VMs
|
||||
4. Configure high availability
|
||||
5. Test failover
|
||||
|
||||

|
||||
|
||||
### Add VLANs in my Homelab
|
||||
|
||||
For this experiment, I create 3 new VLANs:
|
||||
- **VLAN 101**: *POC WAN*
|
||||
- **VLAN 102**: *POC LAN*
|
||||
- **VLAN 103**: *POC pfSync*
|
||||
|
||||
In the Proxmox UI, I navigate to `Datacenter` > `SDN` > `VNets` and I click `Create`:
|
||||

|
||||
|
||||
Once the 3 new VLAN have been created, I apply the configuration.
|
||||
|
||||
Additionally, I add these 3 VLANs in my UniFi Controller. Here only the VLAN ID and name are needed, since the controller will propagate them through the trunks connected to my Proxmox VE nodes.
|
||||
|
||||
### Create “Fake ISP Box“ VM
|
||||
|
||||
To simulate my current ISP modem, I built a VM named `fake-freebox`. This VM routes traffic between the *POC WAN* and *Lab* networks and runs a DHCP server that serves only one lease, just like my real Freebox in bridge mode.
|
||||
|
||||
This VM has 2 NICs, I configure Netplan with:
|
||||
- `eth0` (*POC WAN* VLAN 101): static IP address `10.101.0.254/24`
|
||||
- enp6s19 (Lab VLAN 66): DHCP address given by my current OPNsense router, in upstream
|
||||
```yaml
|
||||
network:
|
||||
version: 2
|
||||
ethernets:
|
||||
eth0:
|
||||
addresses:
|
||||
- 10.101.0.254/24
|
||||
enp6s19:
|
||||
dhcp4: true
|
||||
```
|
||||
|
||||
I enable packet forward to allow this VM to route traffic:
|
||||
```bash
|
||||
echo "net.ipv4.ip_forward=1" | sudo tee -a /etc/sysctl.conf
|
||||
sudo sysctl -p
|
||||
```
|
||||
|
||||
Then I set up masquerading so packets leaving through the lab network wouldn’t be dropped by my current OPNsense:
|
||||
```bash
|
||||
sudo iptables -t nat -A POSTROUTING -o enp6s19 -j MASQUERADE
|
||||
sudo apt install iptables-persistent -y
|
||||
sudo netfilter-persistent save
|
||||
```
|
||||
|
||||
I install `dnsmasq` as a lightweight DHCP server:
|
||||
```bash
|
||||
sudo apt install dnsmasq -y
|
||||
```
|
||||
|
||||
In `/etc/dnsmasq.conf`, I configure to serve exactly one lease (`10.101.0.150`) with DNS pointing to my current OPNsense router, in the *Lab* VLAN:
|
||||
```
|
||||
interface=eth0
|
||||
bind-interfaces
|
||||
dhcp-range=10.101.0.150,10.101.0.150,255.255.255.0,12h
|
||||
dhcp-option=3,10.101.0.254 # default gateway = this VM
|
||||
dhcp-option=6,192.168.66.1 # DNS server
|
||||
```
|
||||
|
||||
I restart the `dnsmasq` service to apply the configuration:
|
||||
```bash
|
||||
sudo systemctl restart dnsmasq
|
||||
```
|
||||
|
||||
The `fake-freebox` VM is now ready to serve DHCP on VLAN 101 and serve only one lease.
|
||||
|
||||
### Build OPNsense VMs
|
||||
|
||||
First I download the OPNsense ISO and upload it to one of my Proxmox nodes:
|
||||

|
||||
|
||||
#### VM Creation
|
||||
|
||||
I create the first VM `poc-opnsense-1`, with the following settings:
|
||||
- OS type: Linux (even though OPNsense is FreeBSD-based)
|
||||
- Machine type: `q35`
|
||||
- BIOS: `OVMF (UEFI)`, EFI storage on my Ceph pool
|
||||
- Disk: 20 GiB also on Ceph
|
||||
- CPU/RAM: 2 vCPU, 2 GiB RAM
|
||||
- NICs:
|
||||
1. VLAN 101 (POC WAN)
|
||||
2. VLAN 102 (POC LAN)
|
||||
3. VLAN 103 (POC pfSync)
|
||||

|
||||
|
||||
ℹ️ Before booting it, I clone this VM to prepare the second one: `poc-opnsense-2`
|
||||
|
||||
On first boot, I hit an “access denied” error. To fix this, I enter the BIOS, go to **Device Manager > Secure Boot Configuration**, uncheck _Attempt Secure Boot_, and restart the VM:
|
||||

|
||||
|
||||
#### OPNsense Installation
|
||||
|
||||
The VM boots on the ISO, I touch nothing until I get into the login screen:
|
||||

|
||||
|
||||
I log in as `installer` / `opnsense` and launch the installer. I select the QEMU hard disk of 20GB as destination and launch the installation:
|
||||

|
||||
|
||||
Once the installation is finished, I remove the ISO from the drive and restart the machine.
|
||||
|
||||
#### OPNsense Basic Configuration
|
||||
|
||||
After reboot, I log in as `root` / `opnsense` and get into the CLI menu:
|
||||

|
||||
|
||||
Using option 1, I reassigned interfaces:
|
||||

|
||||
|
||||
The WAN interface successfully pulled `10.101.0.150/24` from the `fake-freebox`. I set the LAN interface to `10.102.0.2/24` and configured a DHCP pool from `10.102.0.10` to `10.102.0.99`:
|
||||

|
||||
|
||||
✅ The first VM is ready, I start over for the second OPNsense VM, `poc-opnsense-2` which will have the IP `10.102.0.3`
|
||||
|
||||
### Configure OPNsense Highly Available
|
||||
|
||||
With both OPNsense VMs operational, it’s time to configure them from the WebGUI. To access the interface, I connected a Windows VM into the _POC LAN_ VLAN and browsed to the OPNsense IP on port 443:
|
||||

|
||||
|
||||
#### Add pfSync Interface
|
||||
|
||||
The third NIC (`vtnet2`) is assigned to the _pfSync_ interface. This dedicated network allows the two firewalls to synchronize states on the VLAN *POC pfSync*:
|
||||

|
||||
|
||||
I enable the interface on each instance and configure it with a static IP address:
|
||||
- **poc-opnsense-1**: `10.103.0.2/24`
|
||||
- **poc-opnsense-2**: `10.103.0.3/24`
|
||||
|
||||
Then, I add a firewall rule on each node to allow all traffic coming from this network on that *pfSync* interface:
|
||||

|
||||
|
||||
#### Setup High Availability
|
||||
|
||||
Next, in `System` > `High Availability` > `Settings`.
|
||||
- On the master (`poc-opnsense-1`), I configure both the `General Settings` and the `Synchronization Settings`.
|
||||
- On the backup (`poc-opnsense-2`), only `General Settings` are needed, you don't want your backup overwrite the master config.
|
||||

|
||||
|
||||
Once applied, I verify synchronization on the `Status` page:
|
||||

|
||||
|
||||
#### Create Virtual IP Address
|
||||
|
||||
To provide a shared gateway for clients, I create a CARP Virtual IP (VIP) on the LAN interface. It is using the Common Address Redundancy Protocol. This IP is claimed by the active node and automatically fails over.
|
||||
|
||||
Navigate to `Interfaces` > `Virtual IPs` > `Settings`:
|
||||

|
||||
|
||||
To replicate the config, I go to `System > High Availability > Status` and click the button next to `Synchronize and reconfigure all`.
|
||||
|
||||
On the `Interfaces > Virtual IPs > Status` page, the master show the VIP as `MASTER`, while the backup report `BACKUP`.
|
||||
|
||||
#### Reconfigure DHCP
|
||||
|
||||
For HA, I need to adjust the DHCP setup. Since **Dnsmasq** does not support lease synchronization, both instances must serve leases independently.
|
||||
|
||||
On the master:
|
||||
- `Services` > `Dnsmasq DNS & DHCP` > `General`: tick the `Disable HA sync` box.
|
||||
- `DHCP ranges`: also tick the `Disable HA sync` box
|
||||
- `DHCP options`: add the option `router [3]` with the value `10.102.0.1` (LAN VIP)
|
||||
- `DHCP options`: clone the rule for `router [6]` pointing to the same VIP.
|
||||

|
||||
|
||||
On the backup:
|
||||
- `Services` > `Dnsmasq DNS & DHCP` > `General`: also tick the `Disable HA sync` box
|
||||
- Set `DHCP reply delay` to `5` seconds, to give master priority to answer.
|
||||
- `DHCP ranges`: Use a different pool, smaller (`10.102.0.200` -> `220`)
|
||||
- but I also set the value `5` to `DHCP reply delay`. This would give enough time to the master node to provide a DHCP lease before the backup node. In `DHCP ranges`, I edit the current one and give a smaller pool, different than the master's. Here I also tick the `Disable HA sync` box.
|
||||
|
||||
This way, only DHCP options sync between nodes, while lease ranges stay separate.
|
||||
|
||||
#### WAN Interface
|
||||
|
||||
My ISP modem only provides a single DHCP lease, I don't want my 2 VMs compete to claim it. To handle this:
|
||||
1. In Proxmox, I copy the MAC of the `net0` (WAN) interface from `poc-opnsense-1` and applied it to `poc-opnsense-2`. This way, the DHCP lease could be shared among the nodes.
|
||||
⚠️ If both VMs bring up the same MAC, it can cause ARP conflicts and break connectivity, only the MASTER should keep its WAN active.
|
||||
2. CARP event hook provides the possibility to run scripts, I deployed this [Gist script](https://gist.github.com/spali/2da4f23e488219504b2ada12ac59a7dc#file-10-wancarp) in `/usr/local/etc/rc.syshook.d/carp/10-wan` on both nodes. This ensures the WAN is active only on the MASTER, avoiding conflicts.
|
||||
```php
|
||||
#!/usr/local/bin/php
|
||||
<?php
|
||||
|
||||
require_once("config.inc");
|
||||
require_once("interfaces.inc");
|
||||
require_once("util.inc");
|
||||
require_once("system.inc");
|
||||
|
||||
$subsystem = !empty($argv[1]) ? $argv[1] : '';
|
||||
$type = !empty($argv[2]) ? $argv[2] : '';
|
||||
|
||||
if ($type != 'MASTER' && $type != 'BACKUP') {
|
||||
log_error("Carp '$type' event unknown from source '{$subsystem}'");
|
||||
exit(1);
|
||||
}
|
||||
|
||||
if (!strstr($subsystem, '@')) {
|
||||
log_error("Carp '$type' event triggered from wrong source '{$subsystem}'");
|
||||
exit(1);
|
||||
}
|
||||
|
||||
$ifkey = 'wan';
|
||||
|
||||
if ($type === "MASTER") {
|
||||
log_error("enable interface '$ifkey' due CARP event '$type'");
|
||||
$config['interfaces'][$ifkey]['enable'] = '1';
|
||||
write_config("enable interface '$ifkey' due CARP event '$type'", false);
|
||||
interface_configure(false, $ifkey, false, false);
|
||||
} else {
|
||||
log_error("disable interface '$ifkey' due CARP event '$type'");
|
||||
unset($config['interfaces'][$ifkey]['enable']);
|
||||
write_config("disable interface '$ifkey' due CARP event '$type'", false);
|
||||
interface_configure(false, $ifkey, false, false);
|
||||
}
|
||||
```
|
||||
|
||||
### Test Failover
|
||||
|
||||
Time for the real test!
|
||||
|
||||
OPNsense provides a _CARP Maintenance Mode_. With the master active, WAN was enabled only on that node. Entering maintenance mode flipped the roles: the master became backup, its WAN disabled, while the backup enabled its WAN:
|
||||

|
||||
|
||||
While pinging outside the network, I observed zero packet loss during the failover.
|
||||
|
||||
Finally, I simulated a crash by powering off the master. The backup took over seamlessly, I saw only one dropped packet, and thanks to state synchronization, even my SSH session stayed alive. 🎉
|
||||
|
||||
## Conclusion
|
||||
|
||||
This proof of concept showed that running **OPNsense in high availability on Proxmox VE** is possible, even with a single WAN IP address. To achieve this, I needed these components:
|
||||
- VLAN segmentation.
|
||||
- Dedicated pfSync network.
|
||||
- Shared virtual IP.
|
||||
- Script to manage the WAN interface.
|
||||
|
||||
The setup behave exactly as expected, seamless failover, synchronized firewall states, and even live sessions surviving a node crash. The most delicate part was handling the WAN lease, since my ISP modem only provides one IP, but the CARP hook script solved that challenge.
|
||||
|
||||
🚀 The next milestone will be to prepare a new OPNsense HA cluster with the aim to completely replace my current physical box. Stay tuned!
|
||||
Reference in New Issue